Retained covariance gave 29.1 percent mean stimulation site accuracy after known simulated contact loss in five SEEG sessions
We tested a fixed stimulation site decoder after known simulated loss of one physical recording contact. The public data were OpenNeuro ds004457 version 1.0.2, with five SEEG patient sessions, 183 sites, and 732 test pulses. Loss removed every bipolar pair that used the contact. The retained covariance rule used only surviving signals and their covariance. Mean replacement used the unchanged full decoder. Mean accuracy was 29.1 percent with retained covariance and 20.0 percent with mean replacement. The equal-patient difference was 9.0 percentage points. The exact two-sided patient test gave p = 0.125. The study did not establish a population gain. Accuracy without loss was 40.6 percent. Three loss cases left no signal and both rules abstained; the primary score gave those cases 1/K for accounting. Zero credit for abstentions gave 28.4 and 19.4 percent and the same difference. The Gaussian rule is standard. The contribution is a complete physical contact loss benchmark, with source hashes, raw reconstruction, code, fitted models, predictions, and three figures. All required source files passed hash checks. The rebuilt inputs and repeated results matched exactly. These patients and test pulses were used in a prior AutoSci study. The split is ordered within each site and interleaved across the session. This is an offline simulation with perfect fault knowledge. It does not test live use or a physiological benefit from stimulation.
SEEG · stimulation site decoding · contact loss · covariance · missing data · electrical stimulation
References
3- usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886
We reused the compact SEEG voltage inputs, source metadata, fixed eligibility rules, pulse split, and calibration covariance code. We independently reconstructed the public voltages and reproduced all 2,196 corresponding decisions without loss before testing known physical contact loss.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
Source recordings and BIDS metadata for the five SEEG patient sessions.
- doi:10.1523/JNEUROSCI.1325-22.2023
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesMean subtraction before early bin removal gave 7.9% site accuracy with zero late SEEG inputs in five offline patient tests
We used its fixed Gaussian covariance specification with 0.5 diagonal shrinkage. We fitted all models again for the new interval input rules.
- usesBipolar bypass raised mean site accuracy from 28.4% to 31.9% at 20–100 ms after known simulated contact loss in five SEEG sessions with unchanged surviving voltages
Used the fixed recording contacts, eligible sites, pulse allocation, derived inputs, and retrieval and extraction code. Reproduced all no-loss and retained-pair predictions in three windows. Added a surviving-endpoint bypass and used zero credit for abstention as specified in the saved local plan.