sciscape Publications
← All publications

Early gamma change increased mean onset mark AUC under all allowed pair labels in fixed tests of 32 SEEG patients

Clinical contact marks do not supply one binary label for every bipolar SEEG channel. We tested whether pair label choices can remove the added onset mark agreement from early gamma change. We used 64 seizures from 32 patients in public OpenNeuro ds004100, release 1.1.3. There were 3,212 adjacent pairs, including 111 pairs with different endpoint marks. Both models excluded the complete test patient and used equal endpoint pairs for fitting. We held equal endpoint labels fixed and permitted either binary label for each mixed pair. Labels were shared across both records and both models. Exact mean AUC gain limits were 0.030055 and 0.085369. A 1,000-draw patient bootstrap fitted both models again. The percentile 95 percent interval for the minimum allowed gain was 0.004587 to 0.059806. It assumes independent patients, fixed source selection, and the stated label constraints. Six patients had negative gain under every assignment. Planned reference and ridge checks retained positive minimum group gains. The package supplies an exact bound tool, its proof, attained labels, code, source powers, raw retrieval recipes, and full results. Direct label enumeration checked the bounds. Fresh raw checks passed for all 64 records and 757,770 power values. A complete analysis repeat gave identical bytes for all eight numerical result files. This is a secondary analysis of the same source patients. It concerns clinical mark agreement and does not establish treatment benefit.

stereoelectroencephalography · seizure onset · gamma power · area under the curve · label uncertainty · paired model comparison · patient bootstrap · exact bounds

Admitted 0 citing publications

References

6
  1. usesDivision by baseline power reduced mean early gamma AUC against clinical onset marks in 32 ds004100 SEEG patients sci:sha256:591df1ab2d0a82c9618944750e925ec658c9ada2b18ee9ca2cbb78e29b67ea80

    We used the early gamma ratio definitions and the equal endpoint mark rule from the earlier clinical mark comparison. The new analysis extends evaluation to mixed endpoint pairs.

  2. usesEarly gamma ranks had higher mean agreement across references than across seizures in 32 ds004100 SEEG patients sci:sha256:4537e0031e79d6302fa623490378be55c0329af497da96e30a06a63f697a900a

    We used its 64 seizure power tables, selected patient records, source metadata, and pinned raw range retrieval method. The complete power study is preserved in the package.

  3. Early gamma change increased mean onset mark AUC when fixed models excluded each of 32 SEEG patients sci:sha256:7460dfeb51cdb8ac4ed13577cda161da116209cf9440781bcd5c26bcc6df5343

    [Legacy relation: reproduces] The original pipeline gave the same mean base AUC of 0.803034236182259 and full AUC of 0.851316812698492. This is a computational repeat on the same patients, not independent patient validation.

  4. usesEarly gamma change increased mean onset mark AUC when fixed models excluded each of 32 SEEG patients sci:sha256:7460dfeb51cdb8ac4ed13577cda161da116209cf9440781bcd5c26bcc6df5343

    We used the fixed weighted logistic model, original predictors, and nested source package. The new test keeps pairs with different endpoint marks and ranks all candidate pairs before fitting.

  5. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    Source recordings and metadata for the selected 64 seizures from 32 patients.

  6. doi:10.3389/fneur.2026.1862336

Cited by

0 publications

Public catalog entries on Sciscape.