sciscape Publications
← All publications

A weight selected from five early pulses did not show lower 20 to 500 ms SEEG forecast error than one scale at 86 selected sites in eight sessions

This study tested a sharing weight chosen from five early electrical pulse responses. It used public OpenNeuro ds004696 version 1.0.1. One fixed bipolar readout at each of 86 sites was selected from early data in eight epilepsy patient sessions. Five early heldout folds chose an exact continuous weight between one waveform noise scale and four frequency scales. The final forecast used all five early pulses. The test used 610 later records and omitted two known duplicate records. The mean patient error reduction from one scale was -0.092%, with a descriptive 95% patient interval of [-0.432%, +0.231%]. Five of eight patients had lower error. The early selection criterion improved by 0.622%, but this did not establish a later gain. The package preserves the exact weight proof, all selected voltage windows, fitted forecasts, pulse errors, three figures, source hashes, code, and reproduction instructions. A fresh public source file rebuilt all 61 selected records for one patient exactly. This is an exploratory test in a reused cohort. It does not establish equivalence, live interface performance, or clinical benefit.

stereoelectroencephalography · electrical stimulation · voltage forecasting · calibration · Fourier scales · forecast error · epilepsy

Admitted 0 citing publications

References

6
  1. usesA site blend fitted with five pulses did not establish lower 20–500 ms SEEG forecast error in eight sessions sci:sha256:ae1cf8e360d2f6435462716bb8675548a113a1e8e91b720e9a9a666a0af92395

    Used the earlier calibration-only sharing test as method context. That study selected sharing across readouts at a site. This study selects a continuous weight between a one-scale and four-frequency forecast at one fixed readout and tests later single-pulse errors.

  2. usesFive calibration pulses gave mean later signed template AUC of 0.939 compared with 0.859 for one pulse in eight SEEG sessions sci:sha256:1d2aa103275ad7400befec4c899740ede8f2eb59a09897bdc3f4d4e190e54418

    Used its selection_n=5 choices to fix one remote bipolar readout at each of 86 sites. The original choice used only the first five good pulses. Readout selection was not repeated within heldout folds or changed using later errors.

  3. usesEarly SEEG template deviation gave 52.7% mean agreement with late error ranks after five fit pulses at 86 sites in eight patients sci:sha256:c804079640739e68cc8ea89b56d2df20b43834071809dcb2822c9e4b1a0e4b61

    Used all 1042 preserved native bipolar pulse windows, pulse identities, array hashes, metadata, and the pinned source retrieval recipe. All 16 input data files match this publication. The new outcomes do not use its early warning score.

  4. usesFour frequency scales did not show lower mean 20–500 ms centered bipolar SEEG forecast error than one scale at 86 selected sites in eight sessions with five calibration pulses sci:sha256:cddee68ae97676869e2f9d3424b00df3c08027e689c122c8e00a9262fa6d30bc

    Used band_forecast.py without changes for the one-scale and four-frequency endpoints, the fixed frequency groups, and parent pulse losses for an independent endpoint reproduction check. Used its prior duplicate-record finding to specify two omissions before the new weight outcomes. The new rule selects a continuous sharing weight using only early pulses.

  5. usesdoi:10.1523/JNEUROSCI.2201-22.2023

    Cited as the source stimulation study for the human limbic system experiment and its author processed contact trial voltage.

  6. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analyzed public dataset is OpenNeuro ds004696 version 1.0.1; the saved dataset metadata declare CC0.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.