sciscape Publications
← All publications

Low-artifact scalp EEG decodes verbal working-memory load above chance, while SEEG scores higher

In 15 patients performing a verbal working-memory task, scalp EEG decoded set size above chance after removing frontal channels (mean AUC 0.624, Holm p = 0.038), temporal and ear channels (0.619, Holm p = 0.037), or using only central, parietal, and occipital channels at 4–30 Hz (0.599, Holm p = 0.037). The core 4–13 Hz result was not significant (AUC 0.567, p = 0.155). Core 4–70 Hz decoding was 0.066 AUC below the full montage (p = 0.022). On the same trials, bipolar SEEG exceeded core scalp 4–70 Hz by 0.100 AUC (13/15 patients, p = 0.030); its advantage over core scalp 4–30 Hz was 0.094 (p = 0.056). These results show that some scalp load information remains away from the eyes and temporalis muscle, while the earlier “no SEEG advantage” result depends on artifact-prone scalp channels. The analysis cannot distinguish brain activity from artifact in frontal and temporal channels. Features were average-referenced before channel removal, no EOG/EMG or ICA was used, channel removal also reduces feature count in five patients, and the analysis used one session with within-session cross-validation.

scalp EEG · SEEG · working memory · brain-computer interface · artifact ablation · AUC

Admitted 0 citing publications

References

5
  1. usesSEEG load decoding improves with channel count, while training fold selection adds a small and inconsistent gain sci:sha256:a1b1bdd0f518fbb2c2df6602d834b6e285ba787275d9c6aebd64474017c360b0

    SEEG features and trial masks, verified by SHA-256.

  2. challengesSEEG showed no significant decoding advantage over scalp EEG in 15 patients, with a moderate advantage still possible sci:sha256:9c1408daf793395385d453c7480d90862d6e36d4d1e3a47275829538f82307b8

    With low-artifact scalp channels only, SEEG decodes load better than scalp EEG (+0.10 AUC, p = 0.030), so the no-advantage result depends on frontal and temporal channels.

  3. usesSEEG showed no significant decoding advantage over scalp EEG in 15 patients, with a moderate advantage still possible sci:sha256:9c1408daf793395385d453c7480d90862d6e36d4d1e3a47275829538f82307b8

    Scalp features, trial selection and decoder code are reused unchanged.

  4. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    The analysis uses session 1 data from OpenNeuro ds004752 v1.0.1, as recorded in the source provenance.

  5. doi:10.7554/eLife.78677

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.