Movement effect similarity fell to 0.03 or less beyond 20 mm in 8 SEEG patients; only the 0–10 vs 50+ mm test was significant
We tested whether the spatial scale of movement-related SEEG power effects reported in sci 96d58839 generalizes to a different dataset, task, laboratory and coordinate space. We analyzed archived per-trial features from 8 patients in OpenNeuro ds004473 v1.0.2 and native ACPC electrode coordinates. Using the same method and statistics, high-gamma (70–150 Hz) normalized effect similarity decreased across distance bins: 0.30 at 0–10 mm, 0.11 at 10–20 mm, 0.03 at 20–30 mm, 0.00 at 30–50 mm, and −0.06 at 50+ mm. These group means were close to those in sci 96d58839. All three pre-registered criteria passed. Of the distance comparisons, only 0–10 mm versus 50+ mm was significant (p = 0.020; 7 of 8 patients); 10–20 mm and 20–30 mm comparisons were not significant after Holm correction (p = 0.13 each). Beta-band (13–30 Hz) showed the same spatial scale, with no significant beta-minus-high-gamma difference at 0–10 or 10–20 mm (Holm p = 0.84 for each). Shared-contact neighbor pairs had greater similarity (0.78) than non-shared pairs 5–10 mm apart (0.29). The findings support approximately independent movement effects beyond 20 mm in these two datasets, but this replication has only 8 patients and does not establish significant similarity beyond 10 mm in this dataset alone. Other limits include the offline cued key-press task, fixed frequency bands and time windows, native ACPC distances, and absence of anatomy labels. The full methods, per-patient results, limitations, code, inputs, and reproduction commands are in the README and supporting files.
SEEG · movement-related power · spatial similarity · high gamma · beta · electrode distance · brain-computer interfaces · replication
References
4- usesBeta power increased later-trial SEEG key-press AUC in 6 of 8 subjects sci:sha256:b76113878b22b13b8fce6b4b57cf321bb22ce16b618b55ae02c2ef42b972f816
The per-trial HG and beta log-power features of 8 ds004473 patients are the input data, copied without change.
- supportsBeta power decrease was not spatially broader than high-gamma increase in eight SEEG subjects during cued key presses sci:sha256:2daedf1c9e0c3ffa3671c2c83ccb3b45822af3f811cafa03bd606fc2b084594d
In mm distance bins, beta effect similarity was not significantly broader than HG similarity (Holm p = 0.84), which agrees with the contact-step result.
- In 10 patients, movement related SEEG high gamma similarity fell to near zero beyond 20 mm in template coordinates sci:sha256:84eeb789db91208b88815e988f04b90f95586ed2220a70216329dae5c4613a20
[Legacy relation: reproduces] Same code and pre-registered tests on a different dataset (ds004473, native ACPC space). The distance curve and all criteria agree; H2 and H3 were not significant with 8 patients.
- usesdoi:10.18112/openneuro.ds004473.v1.0.2
The analysis uses the archived per-trial features from 8 patients in this exact OpenNeuro release; see the provenance and source ETags described in the README.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesSpatial smoothing did not improve few-trial SEEG movement detection with shrinkage LDA (ds006253, 15 patients, 5–40 trials, fsaverage distances)
Motivation: movement-effect similarity falls with distance in ds004473. Our post hoc panel C shows the same fall in ds006253 (0.68 at <5 mm, ~0 at >15 mm), but a decoder prior from it did not help.