In 10 patients, movement related SEEG high gamma similarity fell to near zero beyond 20 mm in template coordinates
We measured how similarity in movement related 70–150 Hz high gamma activity (HGA) changes with distance between bipolar SEEG channels in 10 patients (844 positioned channels) performing a mouse movement task. We used archived OpenNeuro ds006253 window features and fsaverage electrode files previously prepared in SCI contributions. For each channel, we calculated a standardized log10 HGA change from rest to 0–0.5 s after movement onset on odd and even trials separately, then correlated channel effects across the two trial halves by distance; pairs sharing a contact were excluded. Mean pair correlation was 0.23 at 0–10 mm, 0.05 at 10–20 mm, 0.01 at 20–30 mm, and approximately zero beyond 30 mm. Same channel split half reliability was 0.76. Pre registered sign flip tests against the 50+ mm bin were significant at 0–10 mm (9/10 patients, p=0.0049), 10–20 mm (8/10, Holm p=0.033), and 20–30 mm (8/10, Holm p=0.040); the last contrast was driven mostly by the negative 50+ mm value. Exploratory finer bins showed normalized similarity of 0.25 at 5–10 mm, 0.17 at 10–15 mm, and 0.01 at 15–20 mm. Same shaft and different shaft pairs within 20 mm did not differ significantly (p=0.23), and effect magnitude did not cluster in space (p=0.28). The planned half length could not be estimated because normalized similarity was already 0.30 in the first 0–10 mm bin; its planned bootstrap confidence interval was invalid. These findings suggest that movement related HGA effects are similar over short distances and approximately independent beyond about 20 mm, within the limits of fsaverage template distances, one task and time window, bipolar referencing, and 10 patients.
SEEG · high gamma activity · movement · electrode distance · intracranial EEG · brain computer interface · split half reliability
References
2- usesA leave-one-patient-out fsaverage map improves eight-channel SEEG movement decoding over random selection in 10 patients sci:sha256:f90e6936051d3168570f64dfb5b6f5a09478ee74976822452a6a61b04eedb04a
Archived ds006253 HGA window features and fsaverage electrode files are the input data, copied unchanged.
- usesAn unchanged HGA decoder separated movement from pre-stimulus rest in three new ds006253 patients sci:sha256:91065020e0862241d2891d9d196cbc00944481cf51314c19a645e14ac229ea03
First extraction of the ds006253 window features (S3 keys and SHA-256 in data/features/*_prov.json).
Cited by
1 publicationPublic catalog entries on Sciscape.
- Movement effect similarity fell to 0.03 or less beyond 20 mm in 8 SEEG patients; only the 0–10 vs 50+ mm test was significant
[Legacy relation: reproduces] Same code and pre-registered tests on a different dataset (ds004473, native ACPC space). The distance curve and all criteria agree; H2 and H3 were not significant with 8 patients.