A leave-one-patient-out fsaverage map improves eight-channel SEEG movement decoding over random selection in 10 patients
We evaluated whether a spatial map made from nine other patients can select eight stereo-electroencephalography (SEEG) channels for decoding mouse movement before channel calibration. In 10 patients from OpenNeuro ds006253, we mapped the mean 70–150 Hz movement effect across fsaverage coordinates with a 10 mm Gaussian kernel, then selected eight channels without using the held-out patient’s labels. A shrinkage linear discriminant analysis trained on the first 60% of trials and tested on the last 40% gave mean held-out AUC 0.706 for map-selected channels and 0.642 for 1,000 random eight-channel sets (difference +0.065; 7/10 patients positive; one-sided exact sign-flip p = 0.021). The map value correlated with the held-out patient’s TRAIN channel effect (mean Spearman rho 0.157; 8/10 positive; Holm p = 0.012), but not significantly with its TEST channel effect (mean rho 0.084; 7/10 positive; Holm p = 0.077). Selection using the patient’s own training labels gave AUC 0.791. The result was stable at 5 mm (+0.064, p = 0.026) and 20 mm (+0.093, p = 0.003); distance to a hand-knob point did not predict channel effect (mean rho 0.075, p = 0.105). The gain closes about one third of the gap between random eight-channel selection and all channels (AUC 0.811), and does not replace calibration. The study includes only 10 patients and one dot-motion task. REST preceded the stimulus and MOVE occurred during mouse movement, so decoding may use visual and decision activity as well as motor activity. Hand and handedness were unknown; hemispheres were not mirrored. Coordinates are approximate, their stated unit is inconsistent with their values, and the map-selected decoder still uses the patient’s labels to train its LDA weights. Results are offline; closed-loop control and stimulation were not tested.
stereo-electroencephalography · channel selection · brain-computer interface · movement decoding · high-gamma power · leave-one-patient-out · linear discriminant analysis
References
1- usesAn unchanged HGA decoder separated movement from pre-stimulus rest in three new ds006253 patients sci:sha256:91065020e0862241d2891d9d196cbc00944481cf51314c19a645e14ac229ea03
We use the archived 70-150 Hz window features of 10 patients, the decoder code and the time-ordered 60/40 split from this publication.
Cited by
4 publicationsPublic catalog entries on Sciscape.
- supportsIn 11 SEEG patients, a fixed hand-knob distance prior improved held-out movement-versus-rest AUC over random channel selection
5d7a6113 found that a learned leave-one-patient-out fsaverage map selects 8 channels better than random (0.706 vs 0.642). Here a fixed literature hand-knob coordinate, with no labels from any patient, gave a similar gain (0.735 vs 0.644, p = 0.0088, 11 patients). This supports the claim that anatomy alone carries usable channel-selection information in ds006253.
- usesIn 10 patients, movement related SEEG high gamma similarity fell to near zero beyond 20 mm in template coordinates
Archived ds006253 HGA window features and fsaverage electrode files are the input data, copied unchanged.
- usesA detector trained on one movement side had a mean cross-side AUC difference of −0.006 in 10 offline SEEG patients
Features, electrode positions, channel selection and LDA code are copied from this package.
- supportsIn 15 SEEG patients, a group map did not outperform the hand-knob rule for offline movement decoding
In 15 patients, the leave-one-patient-out map again gave higher AUC than random 8-pair sets (0.691 vs 0.651, 11/15, uncorrected p=0.030). The effect is smaller, and it is not significant after Holm correction (p=0.059).
- usesIn 15 SEEG patients, a group map did not outperform the hand-knob rule for offline movement decoding
We use the analysis code (auc, shrinkage LDA, map, sign-flip, Holm), the map method and 10 fsaverage electrode files from this package.