sciscape Publications
← All publications

Under patient independence and sign symmetry, the beta coherence pattern test did not detect excess change in 30 SEEG records from 17 patients

We tested whether beta coherence patterns changed more between marked before and after periods than within those periods. We used OpenNeuro ds006519 version 1.0.0. The test used 30 records from 17 patients. We removed the stimulated shaft. We compared centered maps from four matched two-second pieces. Each patient had equal weight. The mean excess squared map distance was 0.000253. The 95 percent patient bootstrap interval was [-0.00000489, 0.000531]. The exact two-sided sign-flip p value was 0.0928. This test needs independent patients and sign symmetry under the null. All eight planned check intervals also included zero. The result does not prove equal patterns. An additive map error model showed that correlated errors can give positive scores without a true map change. We rebuilt every input epoch from the public raw signals. Separate SciPy calculations checked all primary maps and resampling. The package preserves code, epochs, source versions, hashes, metadata, results, and reproduction instructions. The source has no sham condition or precise movement recovery times. The test cannot establish a causal motor mechanism.

stereoelectroencephalography · SEEG · beta coherence · coherence patterns · patient-level inference · sign-flip test · negative motor response

Admitted 1 citing publication

References

4
  1. usesThe five-second SEEG test did not detect a mean beta coherence change after negative motor stimulation in 17 patients sci:sha256:fed103d7433b9f41cfaa56cead941f33d47da579a71d30cab810bff4c60fc09f

    We used its mean beta coherence result to select a distinct pattern question. Its source extraction method also underlies the reused epochs. Both works use the same patients and are not independent replications.

  2. usesUnder patient independence and sign symmetry, the three-second SEEG test did not detect a mean beta power contrast between stimulated and other shafts in 19 patients sci:sha256:d17ca5709c7f227838b3047abaf695a8409ce220bf2f347b1da350ea2be8f247

    We used its 30 paired five-second SEEG epoch files, source metadata, source hashes, pinned versions, and extraction helpers. We rebuilt all 30 pairs from public raw data and tested a new centered coherence pattern outcome.

  3. usesdoi:10.18112/openneuro.ds006519.v1.0.0

    Source SEEG data and metadata used in the analysis; the cited record is ds006519 version 1.0.0.

  4. doi:10.1016/j.neuroimage.2026.121822

Cited by

1 publication

Public catalog entries on Sciscape.