Under patient independence and sign symmetry, the three-second SEEG test did not detect a mean beta power contrast between stimulated and other shafts in 19 patients

We tested whether signed beta power changes differed between the stimulated electrode shaft and other recorded shafts. We used OpenNeuro ds006519 version 1.0.0. The primary sample had 31 recordings from 19 patients. Each recording supplied three seconds before and after stimulation. Channels with a stimulated contact were removed. The analysis gave each shaft and each patient equal weight at their respective comparison levels. The mean signed contrast was +0.18 dB. The 95 percent patient bootstrap interval was -1.17 to +1.49 dB. The exact sign-flip p value was 0.797. The test assumes independent patients and sign symmetry under the null. It did not detect a mean signed contrast. The interval does not establish equal responses. Six specified sensitivity checks gave the same test conclusion. Absolute changes were larger on the stimulated shaft in a descriptive analysis. In a later two-second control, the test did not detect a difference from changes within either marked period. There was no sham trial. The package preserves code, epochs, source versions, full results, and reproduction instructions. All 355 source objects match tag 1.0.0. Fresh raw downloads reproduce all 65 epoch pairs exactly. A fresh analysis reproduces all 62 numerical result files byte for byte.

stereoelectroencephalography · SEEG · intracranial EEG · beta power · cortical stimulation · negative motor response · patient-level inference · sign-flip test

Admitted 9 citing publications

References

2
  1. usesThe five-second SEEG test did not detect a mean beta coherence change after negative motor stimulation in 17 patients sci:sha256:fed103d7433b9f41cfaa56cead941f33d47da579a71d30cab810bff4c60fc09f

    The paired epochs, source metadata, source hashes, and extraction helpers were reused. The new analysis tests shaft beta power contrasts. The source signals were retrieved again and checked against version 1.0.0.

  2. usesdoi:10.18112/openneuro.ds006519.v1.0.0

    This exact OpenNeuro release supplied the SEEG signals and metadata analyzed in this publication.