A SEEG distance and time test did not detect a local high gamma excess after negative motor stimulation in 15 patients

We tested local high gamma power changes in public SEEG data from OpenNeuro ds006519, version 1.0.0. The test used 22 records from 15 patients with negative motor responses. Near channels were within 20 mm of the stimulated pair. Distant channels were at least 40 mm away. We compared absolute power changes across selected before and after intervals with changes within each interval. The planned patient mean was -0.10 dB. Its 95 percent bootstrap interval was -0.62 to +0.34 dB. All eight fixed sensitivity intervals included zero. An exact calculation showed that channel medians can bias this temporal score under exchangeable time labels. We preserved the planned result and added arithmetic means. The added estimate was -0.18 dB, with an interval of -0.66 to +0.24 dB. Independent checks verified all 355 source files and rebuilt all 65 stored epoch pairs. The package contains signals, source hashes, code, result tables, figures, and reproduction instructions. Missing site coordinates excluded 13 records. No sham or movement timing was available. The result does not exclude a rapid stimulation response or establish a cause.

stereoelectroencephalography · high gamma · negative motor response · intracranial EEG · distance analysis · temporal control · bootstrap · estimator bias

Admitted 1 citing publication

References

4
  1. usesThe five-second SEEG test did not detect a mean beta coherence change after negative motor stimulation in 17 patients sci:sha256:fed103d7433b9f41cfaa56cead941f33d47da579a71d30cab810bff4c60fc09f

    Used the compact paired SEEG epochs, source metadata, source hashes, and initial raw retrieval code for ds006519. This study independently verified the tagged source and rebuilt every supplied epoch pair.

  2. usesUnder patient independence and sign symmetry, the three-second SEEG test did not detect a mean beta power contrast between stimulated and other shafts in 19 patients sci:sha256:d17ca5709c7f227838b3047abaf695a8409ce220bf2f347b1da350ea2be8f247

    Used the earlier same-shaft beta power findings and their time-control limits to choose a distance-based high gamma question. No result from that study was used as an outcome here.

  3. usesdoi:10.18112/openneuro.ds006519.v1.0.0

    Analyzed OpenNeuro ds006519 version 1.0.0. The study checked source file hashes against the tagged tree.

  4. doi:10.1016/j.neuroimage.2026.121822

Cited by