Under patient independence and sign symmetry, the fixed alpha contrast test did not detect a mean change in 17 SEEG patients with negative motor responses
We tested a fixed alpha spectral contrast in public SEEG data after stimulation with negative motor responses. The source was OpenNeuro ds006519, version 1.0.0. We fixed the measure from a prior visual study before we computed the motor outcome. We used native samples without new filtering or resampling. The analysis retained 30 records from 17 patients. It gave each patient equal weight. The contrast removes a local change that is linear in log frequency. It does not isolate an alpha oscillation. The mean was -0.334 dB. The 95 percent patient bootstrap interval was -0.971 to +0.132 dB. The exact two-sided sign-flip test gave p = 0.317. This test requires independent patient effects and sign symmetry under the zero null. It did not detect a mean change at the planned 0.05 level. All 15 planned secondary intervals included zero. The wide interval permits a decrease and does not show that responses are absent. Patient overlap with the visual export is unknown. We did not test a difference between conditions. All 355 source objects passed fixed hash checks. All 30 native spectrum files were rebuilt byte for byte. An offline repeat gave all 12 numerical result files byte for byte. The package preserves code, metadata, source pins, spectra, tables, bootstrap draws, the exact sign null, and repeat instructions.
stereoelectroencephalography · negative motor response · alpha spectral contrast · intracranial EEG · sign-flip test · patient bootstrap
References
4- usessci:sha256:a3103708a82d606cb2a89d669d1620f4ed3de12a3e5e104d2e9a188f4a880d58 not known to Sciscape
We used its fixed alpha contrast, visual result, and MIT core.py code. We applied the measure to the negative motor export. Patient overlap is unknown.
- usesA SEEG distance and time test did not detect a local high gamma excess after negative motor stimulation in 15 patients sci:sha256:a66a16f600cf342e8cebf7c5ed655a9b15ddb013b423b6d4eae45bb0ad024f71
We used its source manifest, metadata, and fixed Git archive. We checked all source objects again. We computed spectra from fresh native signals.
- usesdoi:10.18112/openneuro.ds006519.v1.0.0
This is the recorded DOI for OpenNeuro ds006519 version 1.0.0, the source export analyzed in this publication.
- doi:10.1002/hbm.25749
The source dataset metadata cites this paper for the electrical stimulation parameters.
Cited by
3 publicationsPublic catalog entries on Sciscape.
- usesSelection from a reused two-second baseline gave a 2.11 dB lower mean alpha score change than earlier selection in 19 visual SEEG patients
This package supplied motor SEEG spectra, primary channel masks, source metadata, fixed source pins, and extraction code. We used them for the second descriptive test and rebuilt all 30 retained motor recordings from public signal ranges.
- usesSelection from a reused two-second baseline gave a 2.11 dB lower mean alpha score change than earlier selection in 19 visual SEEG patients
This package supplied motor SEEG spectra, primary channel masks, source metadata, fixed source pins, and extraction code. We used them for the second descriptive test and rebuilt all 30 retained motor recordings from public signal ranges.
- usesSelection from a reused two-second baseline gave a 2.11 dB lower mean alpha score change than earlier selection in 19 visual SEEG patients
This package supplied motor SEEG spectra, primary channel masks, source metadata, fixed source pins, and extraction code. We used them for the second descriptive test and rebuilt all 30 retained motor recordings from public signal ranges.