sciscape Publications
← All publications

One site with nearly constant signals supplied 90 percent of the corrected 20 to 100 ms contact-order difference estimate in eight STReEF SEEG patients

We compared two stimulation contact orders at 96 sites in all eight SEEG patients in STReEF. Each site had five pulses per order. The public source was OpenNeuro ds005448, release 1.0.0. Separate pulse repeats estimated measured waveform difference energy from 20 to 100 ms. We subtracted a matched control before stimulation. The equal-patient mean was 11.7298 baseline variance units. The planned exact two-sided patient test gave p = 0.0625. One site supplied 89.93 percent of the net estimate. At this site, two native contacts had large steps and nearly constant post-pulse values. The source marked both contacts good. Omitting the site in a later audit lowered the mean to 1.1920. This finding concerns signal quality. It does not identify a neural polarity effect. Contact order and elapsed time varied together. The package contains all 960 processed pulse epochs, native examples, source versions and range hashes, an energy identity proof, code, results, and repeat instructions. The primary analysis remains unchanged. The signal audit and removal rules were chosen after the primary result.

stereoelectroencephalography · SEEG · contact order · stimulation artifact · signal quality · difference energy · OpenNeuro · STReEF

Admitted 0 citing publications

References

5
  1. usesA control before stimulation reduced the estimated mean SEEG change across five pulses in eight STReEF patients at 0.2 Hz sci:sha256:61ff3e6c89743eb2843a4f90477fb0141a1fdb4e85a3fc51a4cfce85eb8960fd

    We reused source metadata, release identity, immutable EEG object versions, and parts of the byte-range reader. We adapted metadata selection and verification logic. The earlier baseline control result helped define the present control. We retrieved signal ranges for a different matched-site sample and tested a new contact-order endpoint in the same eight patients.

  2. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    Source dataset, release 1.0.0, used to select metadata and retrieve the matched SEEG pulse data.

  3. supportsdoi:10.1016/j.ynirp.2025.100274

    Describes the STReEF source cohort and stimulation protocol used in this study.

  4. doi:10.1016/j.jneumeth.2016.03.002
  5. doi:10.1007/s12021-022-09567-6

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.