Centered median templates raised mean site accuracy with one simulated wrong label per four fit pulses and lowered clean accuracy in five SEEG sessions at 20 to 100 ms
We tested whether a centered coordinate median reduces errors from wrong stimulation-site labels in a four-pulse fit. Public OpenNeuro ds004457 version 1.0.2 supplied five SEEG sessions, 183 sites, 732 fit pulses, and 732 separate test pulses. Each site had one wrong fit label in 64 draws per patient. Each draw reassigned recorded fit pulses and preserved all voltages. Both readers used the same mean-residual covariance fitted from the changed labels. At 20 to 100 ms, the median raised equal patient accuracy from 30.88% to 32.34%, a gain of 1.47 percentage points. Four patients gained and one lost. With clean labels, accuracy fell from 40.56% to 37.99%, a loss of 2.57 points. All five patients had a clean loss. The descriptive 95% patient bootstrap interval for the error gain was 0.25 to 3.05 points. The exact two-sided patient sign-flip value was 0.125. This small sample does not establish a population gain. The package provides a fixed calibration-label benchmark, three figures, voltage bins, all label maps and decisions, models, code, source hashes, and repeat instructions. Fresh raw extraction matched the input arrays. Direct analysis of the rebuilt inputs matched all 22 numerical files. An independent calculation matched all 566,568 saved decisions. These repeated decisions are not independent observations. The clinical cohort was reused. Only 36 test pulses occurred after all site fits. The study does not test a live BCI, real label faults, or a unique neural signal.
SEEG · brain-computer interface · stimulation responses · coordinate median · label errors · template classification · calibration · offline benchmark
References
5- usesPulse time alone gave 74.8% mean site accuracy in five offline SEEG tests with shared calibration and test blocks sci:sha256:07f3c9173d8e02cafb724475eb4d7d43bb6e6bf6e042867f73744b4ea8895b75
Its timing-only audit informed the schedule limit and the choice to avoid repeating that question. We recomputed that only 36 of 732 test pulses occur after all fitting pulses. The present result remains an offline calibration-label test.
- usesA contact mixture raised mean 20 to 100 ms site accuracy under hidden simulated contact errors at ten times the fitted voltage scale in five SEEG sessions sci:sha256:1fe087ca2edf92bb930844bed18a6b825f82b783043f5bfea4f0cbc51ef01231
We reused its checked ds004457 voltage bins, fixed recording contacts, site eligibility, source manifest, and retrieval and extraction utilities. We tested new fit-label permutations, not its simulated contact voltage errors.
- usesMedian templates raised four-site SEEG accuracy from 71.9% to 75.6% in eight patients with five fit pulses per site and fixed four-pair scales sci:sha256:b19cb0d6c58ede7a282d61eaf231d075c723dde136d98ded6ed1f219ca317d27
Its clean mean and median comparison in another SEEG dataset informed the template comparison. Our new test uses four fit pulses and simulated wrong site labels in ds004457. We used no code or data from this prior.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
Source dataset used for the five SEEG sessions; the preserved source manifest records release file identifiers and hashes.
- doi:10.1523/JNEUROSCI.1325-22.2023
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.