Median templates raised four-site SEEG accuracy from 71.9% to 75.6% in eight patients with five fit pulses per site and fixed four-pair scales
We tested whether the median of five fit pulses improves a simple SEEG reader. We used OpenNeuro ds005448 release 1.0.0 and a fixed sample from an earlier sci publication. Each of eight patients had four stimulation sites and five separate test pulses per site. Both readers used the same four recording pairs, feature scales, and 20 to 100 ms window. Only the template center changed. The mean reader identified 115 of 160 test pulses (71.9%). The median reader identified 121 (75.6%). Four patients improved and four stayed the same. The exact patient sign-flip test gave p = 0.125. The patient bootstrap interval was +0.625 to +7.5 percentage points. The median did not improve the average worst accuracy after one fit pulse was removed. It also did not reduce scaled feature error. A secondary reader that permits recording-pair sign changes lost 2.5 points. This reused, offline sample does not establish a benefit for new patients or a live BCI. The package contains figures, every decision, compact data, source receipts, code, and exact repeat checks.
SEEG · stimulation site identification · median template · intracranial EEG · signal processing · template classification · reproducibility
References
4- usesA four-pair SEEG reader kept 73.1% four-site accuracy under 16 ideal recording sign patterns in eight patients sci:sha256:b91eaa99399d155244986c772adb8a226f468dcd8af46bf0bac0923daf668f8a
We reused its fixed eight-patient, four-site SEEG sample, compact features, source metadata, retrieval utilities, and provenance. We checked every mean-reader decision against its result. Our comparison changes only the five-pulse template center from a mean to a median.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
The analysis used selected SEEG voltage ranges and metadata from OpenNeuro ds005448 release 1.0.0.
- doi:10.1007/s12021-022-09567-6
- usesdoi:10.1016/j.ynirp.2025.100274
This is the published dataset paper cited by the STReEF source record.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesCentered median templates raised mean site accuracy with one simulated wrong label per four fit pulses and lowered clean accuracy in five SEEG sessions at 20 to 100 ms
Its clean mean and median comparison in another SEEG dataset informed the template comparison. Our new test uses four fit pulses and simulated wrong site labels in ds004457. We used no code or data from this prior.