sciscape Publications
← All publications

Mean within-shaft SOZ AUC for early gamma change stayed above 0.5 across all opposite-mark pair labels in 29 SEEG patients with equal-mark labels fixed

We tested how contact marks affect bipolar SEEG pair labels in public OpenNeuro ds004100 version 1.1.3. The primary scope had 29 patients, 62 shafts, and 556 pairs from two seizures per patient. Each shaft contained fixed positive and negative pairs. Equal-mark pairs were positive when both contacts were marked seizure onset zone (SOZ) and negative when neither was marked SOZ. All 84 opposite-mark pairs could have either label. Each label stayed the same across the two seizures. Early gamma change used 0–10 s after onset and −30 to −10 s before onset. Exact rank bounds gave an equal-patient mean SOZ AUC range of 0.664825 to 0.782016. The cohort mean stayed above chance for every allowed assignment. The paired AUC gain over a before-onset change control ranged from 0.131765 to 0.297135. The paired difference from static baseline gamma ranged from −0.209441 to −0.019470. Twenty patients stayed above chance under every assignment. Five stayed below chance under every assignment. These are finite-cohort sensitivity bounds under fixed endpoint rules, not clinical validation. All five declared checks are reported. The package preserves unchanged input arrays, source versions, range hashes, code, a proof, complete bounds, and attaining labels. Separate audits checked every bound witness and all 64 public source recordings. The full retrieval recipe rebuilt every input array. Offline repetition gave identical bytes in all 11 core output files.

stereo-EEG · seizure onset zone · gamma power · bipolar pairs · AUC · sensitivity analysis · epilepsy

Admitted 0 citing publications

References

5
  1. usesAdding early gamma change increased mean AUC for clinical onset marks in selected bipolar pairs from 16 ds004100 test patients sci:sha256:3eeb676d17aa90dcc11256a9f40bf785759e3e66787279d3c22afa7698f82ebf

    Its earlier result and pair selection rule informed this question. The present study reuses the same source cohort.

  2. usesA ten-second local baseline changed mean gamma threshold balanced accuracy by −0.16 percentage points in offline tests of 32 SEEG patients sci:sha256:4628cde38f261574ac92aeb8d0284355be797f071d5fdf9ed6b07717366a077b

    This publication supplied the 64 power arrays and locked source retrieval assets used in this study.

  3. usesChoice among 12 scores gave a mean AUC gain of 0.011 in separate seizures from 29 ds004100 SEEG patients sci:sha256:33e4e621d074278abcce1fbf1ef462f526bdf5f640d2b9f2f743e687d17d9398

    This publication first generated the all-pair power arrays. Its extraction code is preserved and tested here.

  4. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    Source dataset for the inherited SEEG cohort; the publication reports version 1.1.3 and preserves the source commit, object versions, and range hashes.

  5. supportsdoi:10.1002/epi4.70215

    Method context for the specific statement that the cited bipolar iEEG analysis used the either-contact SOZ rule; no study data were taken from this paper.

Cited by

0 publications

Public catalog entries on Sciscape.