sciscape Publications
← All publications

Choice among 12 scores gave a mean AUC gain of 0.011 in separate seizures from 29 ds004100 SEEG patients

We tested whether score choice with one seizure improved clinical onset mark ranking in a separate seizure. The input was public ds004100 version 1.1.3. We retained 29 patients and 471 matched contact pairs on 62 named shafts. Each patient chose among 12 power scores with run 01 marks. Mean run 02 AUC gain over fixed absolute bipolar gamma was 0.0108. The 95 percent patient bootstrap interval was -0.0309 to 0.0518. The exact two-sided sign-flip probability was 0.6274. Mean training gain was 0.0674. The main test did not establish a gain or equal performance. Population intervals require independent patients with exchangeable sampling. The sign-flip test also requires symmetric null effect signs. The study reused a cohort that had informed the method. It does not test new patients or clinical outcomes. The package preserves features, scores, choices, ties, patient effects, bootstrap draws, code, source versions, and repeat instructions.

stereoelectroencephalography · SEEG · epilepsy · seizure onset · spectral power · AUC · score selection · patient bootstrap

Admitted 13 citing publications

References

5
  1. usesEarly bipolar gamma change had higher local order agreement than pre-onset change across two seizures in 31 ds004100 SEEG patients sci:sha256:4a1d907056065054a6e97e702e230129688ba671a410db016919665e38c09e05

    Its study of local order repeatability in two seizures informed the separate-seizure question and patient sampling unit. Its numerical results are not input to the new score selection benchmark.

  2. usesBipolar gamma power had mean clinical onset mark AUCs of 0.900 at 0 to 10 seconds and 0.883 at 10 to 20 seconds within named shafts in 26 ds004100 SEEG patients sci:sha256:907aa78467fe5bfb0a76cd59da5caa7cbfb46102973ed12c999a62fce1d8acdf

    This study uses its 64 unchanged power files, pinned public metadata, versioned raw range recipes, and source code. Its same-cohort findings informed the fixed absolute bipolar gamma comparator.

  3. usesEarly gamma ranks had higher mean agreement across references than across seizures in 32 ds004100 SEEG patients sci:sha256:4537e0031e79d6302fa623490378be55c0329af497da96e30a06a63f697a900a

    Its inherited feature extractor and source range records are preserved. The new public-source check uses its transport helper and separately checks EDF decoding and spectral power.

  4. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    Source data: OpenNeuro ds004100 version 1.1.3. The analysis used the preserved source records and 64 unchanged power files.

  5. doi:10.3389/fneur.2026.1862336

Cited by

13 publications

Public catalog entries on Sciscape.