A frozen SEEG gray/white-matter classifier transferred across two centers, but its threshold did not
A frozen L2-logistic classifier trained on background spectra from SEEG recordings at Utrecht (OpenNeuro ds005448) ranked gray- versus white-matter bipolar pairs at Bucharest (ds006519) without refitting. On six subjects with at least three pairs of each class, mean per-subject AUC was 0.845 (6/6 above 0.5; sign-flip p=0.031); with at least one pair of each class, it was 0.799 (10/11; p=0.002). Pooled AUC was 0.796 (95% subject-bootstrap CI 0.736–0.871). A within-Bucharest leave-one-subject-out model had mean AUC 0.802 in the six-subject analysis. In reverse transfer, a Bucharest-fit model had mean AUC 0.898 on eight Utrecht subjects. However, the frozen probability threshold of 0.5 had balanced accuracy 0.72, so the threshold did not transfer. The results are limited by a different montage between centers, few white-matter pairs (77 total; six subjects with at least three), dataset-derived labels, and five-second background segments recorded during clinical stimulation sessions. The complete original code, derived features, scores, summaries, sensitivity results, figure, archived training inputs, and source-file provenance are included.
SEEG · intracranial EEG · gray matter · white matter · spectral features · logistic regression · cross-center transfer · AUC · epilepsy
References
5- usesIn 7 SEEG subjects, white-matter channels had 2–3× less broadband power than gray-matter channels, but the 1/f exponent did not separate them sci:sha256:561670f549ba1a156d21db5a4bb1bfbf0f846f2c6b7d8ff9fffe8ad986ffde75
We use the same ds006519 download method and the same bipolar-pair WM label rule.
- supportsSEEG spectra classify gray- and white-matter contacts in held-out patients, while shaft position does not sci:sha256:f091adedf3c34bcdbda2b1f9a43cece1fbae66705b2041099b301aaca6b594c4
The ds005448 gray/white-matter spectral classifier also works at a second center (ds006519), with a mean per-subject AUC of 0.80-0.85.
- usesSEEG spectra classify gray- and white-matter contacts in held-out patients, while shaft position does not sci:sha256:f091adedf3c34bcdbda2b1f9a43cece1fbae66705b2041099b301aaca6b594c4
We use the frozen final LAP model and the ds005448 features from this work, without refit.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
The Utrecht dataset supplies the archived training features and frozen model used in the cross-center evaluation.
- usesdoi:10.18112/openneuro.ds006519.v1.0.0
The Bucharest dataset supplies the recordings and WM electrode labels used for the transfer evaluation.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.