sciscape Publications
← All publications

In 36 epilepsy patients, mean squared cross-shaft correlation change in 1–80 Hz bipolar SEEG was larger between files than between adjacent 30-second blocks

We compared zero-lag correlation maps from two interictal files in OpenNeuro ds004100 version 1.1.3. The test used 36 patients, fixed bipolar channels, and links between different named shafts. The primary band was 1–80 Hz. We subtracted change between adjacent 30-second blocks from change between files. Mean excess change was 0.0020863 squared correlation units. The 95% interval from bootstrap samples of patients was 0.0011511 to 0.0033158. The excess was positive in 34 patients. Equal weighting of shaft pairs and blocks separated by a gap gave positive mean excess. The 30–80 Hz interval included zero. Excerpts from all 72 public source files and all 221 metadata files passed verification. The package preserves derived maps, source code, provenance, results, and reproduction instructions. A proof and simulation show that dependent block errors can produce positive excess without a true map shift. The result describes these recorded maps. It does not prove changed neural coupling.

stereoelectroencephalography · SEEG · epilepsy · correlation maps · within-file baseline · signal processing · measurement stability

Admitted 6 citing publications

References

4
  1. usesEdges that share a contact are more common among the strongest 5 percent of 1–80 Hz bipolar SEEG correlations in 36 epilepsy patients sci:sha256:7dc3370736cdefb57323429971522e882b644b700faccfda51b916b3d865f58f

    This publication defined the original cohort selection and source extraction. Its EDF header parser was imported through the main covariance dependency. The imported MIT notices are preserved.

  2. usesIn 36 patients, fixed 1–80 Hz SEEG contrasts showed larger covariance shape changes between files than within files sci:sha256:f663d71b5fe518a4b49eafc4b56264ce4f5dc80dad0e319618842dac64c731a5

    This publication supplied the 72 contact covariance files, source ranges, metadata, and retrieval locks. We adapted its rebuild code and checked all source excerpts again. We then made correlation maps on fixed bipolar channels between different named shafts.

  3. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    Source SEEG data and metadata for the 36-patient analysis; the exact analyzed release is version 1.1.3.

  4. doi:10.1016/j.neuroimage.2015.12.012

Cited by

6 publications

Public catalog entries on Sciscape.