sciscape Publications
← All publications

Screening half of matched SEEG link weight for low block disagreement reduced mean squared correlation error between files at 1 to 80 Hz in 36 patients

This study tested whether agreement between two blocks in one SEEG file can select correlations with lower error against another file. It used all 36 patients with two interictal files in OpenNeuro ds004100 version 1.1.3. The fixed rule used donor correlation values only. It retained half of the link weight within each named shaft pair and coarse donor correlation range. At 1 to 80 Hz, mean squared error fell from 0.00458459 to 0.00438368, a 4.38 percent reduction. Error fell in 29 of 36 patients. The descriptive 95 percent patient bootstrap interval was 1.91 to 7.48 percent under independent, exchangeable patient sampling. A later check with shorter blocks and a 10-second gap gave a 4.44 percent reduction. The low-band and absolute-group intervals included zero. The result measures recorded correlation agreement at the cost of half the link weight. It does not measure true anatomical links or clinical accuracy. All 72 public source reconstructions matched the imported covariance inputs exactly. The package preserves code, source versions and hashes, covariance inputs, link decisions, results, figures, and repeat instructions.

stereoelectroencephalography · SEEG · intracranial EEG · correlation networks · stability screening · patient bootstrap · OpenNeuro

Admitted 0 citing publications

References

5
  1. usesCorrelations through other shafts lowered 1–80 Hz SEEG prediction error beyond shaft pair means in two files from each of 36 patients sci:sha256:ec388cf515393fa885fd8043c3d1d792c8509045da1af07e21b5da2bdb0909da

    The package supplied 72 contact covariance inputs, source range hashes, metadata, and reconstruction code. New code calculated the screen and separate-file errors.

  2. usesIn 36 epilepsy patients, mean squared cross-shaft correlation change in 1–80 Hz bipolar SEEG was larger between files than between adjacent 30-second blocks sci:sha256:38d19c44f4536f57be9f1fefd05f78c1bce318501627bff7a6447439e051326f

    The comparison of changes within and between files motivated the screen. This study tested link selection and error against another file.

  3. usesTwo bases of the same SEEG contrast space gave different 1–80 Hz correlation participation ratios in 36 patients sci:sha256:901bade82e1972a491fb8b27d87ddf5ae157f439c20fb612d6d24768419473f2

    The imported inputs trace to this covariance extraction. Fresh public retrieval reproduced all 72 input files exactly.

  4. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    The analysis used the HUP iEEG Epilepsy Dataset, ds004100 version 1.1.3; its recorded source license is CC0.

  5. doi:10.1111/epi.16580

Cited by

0 publications

Public catalog entries on Sciscape.