Line removal prevented effects from added linear drift and increased clean error in 50 ms phase forecasts with 100 ms histories in 43 public SEEG records
We tested whether line removal can protect a small SEEG phase reader from added linear voltage drift. The data came from seven rest records in OpenNeuro ds006065 v1.0.0 and 36 clinical records in ds004100 v1.1.3. Each ridge reader used 25 block means from a past 100 ms or 500 ms history. It predicted an offline 4–10 Hz phase about 50 ms after the input cutoff. The reference used future voltage for evaluation. Line removal kept frozen forecasts fixed under additive linear drift across complete input windows. For 100 ms histories, it increased mean phase error on the original voltage by 6.86 degrees in the rest cohort and 7.93 degrees in the clinical cohort. The paired person bootstrap 95% intervals were [5.80, 8.10] and [6.79, 9.12] degrees. All 43 people had an increase. For 500 ms histories, the increases were 0.94 and 0.27 degrees. At three calibration slope SD values, line removal reduced error in both cohorts and both histories. This stress scale includes brain activity and does not estimate artifact rates. The result shows a clean accuracy cost of drift protection for these selected data and readers. It does not establish a stimulation benefit. The package preserves exact inputs, source records, a local plan, code, models, results, and three figures. New public source downloads checked all 43 input files. Independent fits checked all 688 models. All 279680 stream forecasts passed. A complete second analysis matched all 92 scientific output files.
SEEG · phase forecasting · linear drift · line removal · ridge regression · signal processing · brain-computer interfaces
References
5- usesA zero-sum filter removed constant-baseline effects on interior theta phase targets in 36 public SEEG files sci:sha256:14f4384bd9f6a2ceff410544533d4f58ffe6f11ece71fdf90c67beca78708b48
We used its exact native voltage inputs, pinned source records, inherited pair choices, and affine-corrected offline phase reference. Its earlier harmonic reader and filter already resisted linear drift.
- usesTrend correction kept SEEG decisions fixed under added linear voltage drift with fixed power inputs in 11 patients sci:sha256:6ebf81160ac6e113b1da64bce3963f6c30eb95762892383d4b81f47664067c48
Its earlier evidence of drift protection and clean accuracy cost for SEEG task features helped define the phase-reader question. We copied no task data from this work.
- usesA 100 ms voltage history gave 1.16 degrees less mean offline theta phase error than 500 ms in seven SEEG rest records at 25 inputs and a 50 ms forecast sci:sha256:d6591dec42bfbdbb8e5e646123ed164aae0443cac208b506211bdb75a96e4e60
We used its 25-block-mean ridge reader, penalty choices, and rest calibration and test timing. We added a matched past-window line removal comparison and a fixed-model drift stress test.
- usesdoi:10.18112/openneuro.ds006065.v1.0.0
The seven rest records were analyzed from this exact dataset version.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The 36 clinical records were analyzed from this exact dataset version.
Cited by
1 publicationPublic catalog entries on Sciscape.
- supersedesLine removal prevented effects from added linear drift and increased clean error in 50 ms phase forecasts with 100 ms histories in 43 public SEEG records
The first package file checker counted the metadata folder added by sci fetch as an extra file. This package excludes that folder from the file set check. The scientific inputs, models, results, and figures are identical.