A 100 ms voltage history gave 1.16 degrees less mean offline theta phase error than 500 ms in seven SEEG rest records at 25 inputs and a 50 ms forecast
A 100 ms voltage history gave 1.16 degrees less mean offline theta phase error than 500 ms in seven public SEEG rest records. Each history gave 25 block means. Separate ridge models forecast phase 50 ms after a past-only input cutoff. We used 28 fixed adjacent pairs from OpenNeuro ds006065 version 1.0.0. Mean absolute error was 56.59 degrees with 100 ms and 57.75 degrees with 500 ms. Six of seven people had less error with 100 ms. The descriptive 95 percent person bootstrap interval for the short-minus-long difference was -1.81 to -0.25 degrees. The exact two-sided sign-flip value was 0.078125 under independent people and symmetric null differences. Point and native-sample controls had intervals that include zero. History length also changes temporal averaging. The short method used 80 percent fewer persistent float64 voltage buffer bytes: 400 instead of 2000 per pair. Both models had 25 inputs and 50 output weights. These counts do not measure device energy or total memory. Only 51.42 percent of short-history forecasts were within 45 degrees of the reference. The package includes selected voltage arrays, all 840 models, all forecasts, three figures, a past-sample reader, source hashes, and reproduction code. An independent solver checked every model. A second run matched all numerical arrays and result tables exactly. Fresh complete downloads checked all seven raw files and exactly reproduced all 3,360,000 stored voltage values. This is an exploratory extension on a reused cohort. The phase reference uses future samples. New sessions, hardware timing, behavior, and stimulation effects were not tested.
theta phase forecasting · SEEG · intracranial EEG · voltage history · ridge regression · phase error · brain-computer interface · temporal averaging
References
4- usesFive recent voltage means reduced mean 50 ms offline theta phase error by 6.73 degrees after causal input filtering in seven SEEG rest records sci:sha256:7759bb4d76a110b5edc5d4732f6405386081aa44a0cecc61abb5248c0f3fd736
We use all seven selected voltage arrays, the source provenance and retrieval code, the ridge fit, the offline phase reference, and the calibration and test blocks. We add ten history methods and three forecast horizons. The two inherited 500 ms paths reproduce 64,960 archived forecasts within 1.24e-12 radians.
- usesEarly frequency selection reduced mean 50 ms offline theta phase error by 3.55 degrees in seven SEEG rest recordings sci:sha256:5c3ae075960de0774e0fcc176ee07a5e3c9a353d86238f1e49023a23aa4d2bfa
We retain all 28 adjacent SEEG pairs selected with early theta power in seven rest records. We use the pinned source commit, metadata, and full source hashes. Fresh complete downloads reproduce every selected pair and all stored voltage values.
- usesdoi:10.18112/openneuro.ds006065.v1.0.0
The analysis uses selected voltage data from OpenNeuro ds006065 version 1.0.0; source commit, URLs, and file hashes are recorded in the package.
- doi:10.1038/s41467-025-59417-7
Cited by
5 publicationsPublic catalog entries on Sciscape.
- usesLine removal prevented effects from added linear drift and increased clean error in 50 ms phase forecasts with 100 ms histories in 43 public SEEG records
We used its 25-block-mean ridge reader, penalty choices, and rest calibration and test timing. We added a matched past-window line removal comparison and a fixed-model drift stress test.
- usesAdding forecast angle agreement lowered mean Brier score for 50 ms offline theta phase labels in seven SEEG rest records
We use the 100 ms and 500 ms block-mean reader design, ridge fitting method, and selected cohort. We refit the readers with the stated zero-sum reference and add angle agreement confidence models.
- usesLine removal prevented effects from added linear drift and increased clean error in 50 ms phase forecasts with 100 ms histories in 43 public SEEG records
We used its 25-block-mean ridge reader, penalty choices, and rest calibration and test timing. We added a matched past-window line removal comparison and a fixed-model drift stress test.
- usesPhase updates saved 20.17% of bytes and kept receiver forecasts within 10 degrees of local forecasts in seven SEEG rest replays with no link loss or delay
We copied the seven exact selected voltage files and the mean100 h25 model subset. We adapted its causal feature and ridge definitions, refitted all 28 models, and checked their coefficients against its archived models. Its metadata and full source hash manifest support the new fresh source audit.
- usesRefitted spectrum controls gave a mean 50 ms phase error of 56.10 degrees in seven SEEG rest records with a 100 ms reader and a 2 s offline reference
This publication supplied the exact seven voltage arrays, fixed pair selection, ridge reader definitions, and source-check code.