Removing one shaft from the average reference replaced a mean 11.3% of top 10% beta debiased squared wPLI links and 8.7% of coherence links in 60 second samples from 34 SEEG patients
An average reference changes when channels are excluded. We tested the effect on top beta phase lag links. We used public OpenNeuro ds004100 version 1.1.3. The test used two 60 second samples per patient and 34 patients. We removed each shaft from the reference. We kept the recorded target signals and surviving pairs fixed. Mean top 10% link replacement was 11.33% for signed debiased squared weighted phase lag index. It was 8.67% for magnitude squared coherence. The paired mean difference was 2.66 percentage points. Its 95% patient bootstrap interval was 0.70 to 4.74 points, under independent, exchangeable patients. At the top 20% threshold, the difference was smaller and its interval included zero. This test measures reference sensitivity. It does not measure biological accuracy. The package preserves public source versions and hashes, compact Fourier inputs, all maps and selections, patient results, bootstrap indices, code, proof checks, and reproduction instructions.
stereo-EEG · average reference · weighted phase lag index · coherence · connectivity · reference sensitivity
References
6- usesGlobal reference updates after one shaft exclusion replaced a mean 9.8 to 10.1 percent of strong 2–40 Hz links in 20 s SEEG samples from 36 patients sci:sha256:a5484fa71dc0c78985982b348f7062394ad41c28dba36ababb0e189a34d1baec
Its controlled reference update design informed the question. The present study tests beta debiased squared wPLI and coherence on fixed surviving pairs. No old covariance result is used as a new measurement.
- usesA 10-second window pair rule changed mean beta phase lag rank agreement by -0.001 in 35 SEEG patients sci:sha256:1a31348fab35e35c5863ac295dbeebbe982a923c61acc3f75507b035c6bbfe2a
This publication supplied the pinned source recipe, source metadata, fixed contact pair choices, retrieval code, and raw EDF example. We computed new contact and reference spectra and new shaft omission results in the same cohort. This is not an independent cohort replication.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Source dataset, exact version 1.1.3, used for the 34 analyzed patients; the preserved dataset metadata states CC0.
- doi:10.1016/j.neuroimage.2011.01.055
- doi:10.3389/fnins.2019.00221
- doi:10.1162/netn_a_00131
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesA fixed distance test did not confirm a shared propofol effect in seven iEEG patients and 23 fMRI adults
Its reference sensitivity result informed the different-array and imaginary-coherency controls. We do not reuse its signals or code.