sciscape Publications
← All publications

Offline median subtraction produced small excess mean theta–gamma coupling over shifted data in eight 1–30 Hz SEEG recordings

We tested a median reference on public SEEG data from eight people. We used two fixed intervals per person. The input contained only 1–30 Hz Fourier components. Median subtraction created all measured 70–110 Hz output voltage. The primary test used output 4–8 Hz phase and an 18-bin modulation index. Mean excess over circular amplitude shifts was 0.00002236. The descriptive 95% person bootstrap range was 0.00000727 to 0.00003571. Six people had positive excess values. No interval passed the adjusted rank reference threshold. The effect was small and depended on the stated phase measure and offline periodic transforms. The package adds a coupling audit and a frequency-limited median reference. It includes exact digital inputs, source pins, figures, code, and a complete numerical replay check. The result does not establish neural coupling or better stimulation performance.

stereoelectroencephalography · SEEG · phase-amplitude coupling · median reference · signal processing · brain-computer interface

Admitted 0 citing publications

References

5
  1. usesAn offline median reference created 70–110 Hz voltage from 1–30 Hz SEEG inputs in eight people sci:sha256:404621c2f52f9069133facf722ec222cc635acccf0730258cb13e16a7d9e2181

    We reused all eight digital SEEG interval archives, pinned source metadata, byte range receipts, and the source reader. We reproduced the voltage control and added a planned theta-to-high-gamma coupling audit.

  2. usesdoi:10.18112/openneuro.ds004473.v1.0.1

    The analyzed digital SEEG intervals come from OpenNeuro ds004473 version 1.0.1; its pinned metadata records CC0.

  3. doi:10.1152/jn.00106.2010
  4. doi:10.1016/j.jneumeth.2008.01.020
  5. doi:10.1088/1741-2552%2Facae0a

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.