A matrix forecast with training on other shafts raised mean relative error after one accepted pulse in five SEEG recordings at 20–500 ms
We tested whether a matrix forecast could use one accepted pulse at a site new to the model. The source was OpenNeuro ds004457, version 1.0.2. Five recordings supplied 86 test sites and 15 recording pairs. Training used earlier completed responses on other stimulation shafts. A scalar forecast used the same training data. Both methods used donor data to select their settings. The matrix lowered voltage error in four patients. It raised error by 231.87 percent in the fifth. The mean patient relative error rose by 37.36 percent. The exact sign-flip value was 1.0. A secondary score divided by first-pulse energy showed a 6.82 percent reduction. Thus, the same forecasts gave different conclusions under two losses. All five raw rebuilds matched the stored waveforms. The package contains code, data, forecasts, figures, checks, and a retrieval recipe. This offline voltage test does not establish a brain-computer interface benefit.
SEEG · electrical stimulation · brain-computer interface · voltage forecasting · noise covariance · signal processing
References
5- usesEarlier-site variation lowered error divided by first-pulse energy but raised voltage error versus a fixed half-size SEEG forecast from one pulse at 20–500 ms in eight sessions sci:sha256:58071e3fb743b119318393aab21061a1df0769f447a08d68613ba93511c4afae
Its disagreement between voltage loss and input-scaled loss in another dataset informed our primary loss choice. We used voltage loss as primary and scaled loss as secondary. No data or fitted model from that report were used.
- usesA learned time basis did not show lower mean one-pulse SEEG forecast error at 94 new sites in five patient sessions sci:sha256:7aa30d9799432d4754152e931d764d9f390ea9b971b9c6e176501180aabbeebf
Its learned time basis forecast on the same cohort informed the question about full covariance filtering. Our test uses noise covariance, primary voltage loss, and donors on other stimulation shafts. The site sample and methods differ.
- usesAll earlier pulses gave lower mean SEEG forecast error than four recent pulses in five recordings at 20–500 ms sci:sha256:7572e2f1a54f04ee36ae5756aff12b06f8ed5349904c849467a91c2e6236dbe9
We used its 5 ms SEEG voltage bins, source metadata, raw file manifest, and MIT extraction and retrieval code. We adapted the loader. These inputs enabled the new time-separated matrix-versus-scalar forecast test.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
Source dataset used in the analysis; the recorded version is 1.0.2.
- doi:10.1523/JNEUROSCI.1325-22.2023
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.