sciscape Publications
← All publications

A learned time basis did not show lower mean one-pulse SEEG forecast error at 94 new sites in five patient sessions

A time basis learned from earlier stimulation sites did not show lower mean forecast error than a fixed time basis family. The test used public SEEG data from five patient sessions in OpenNeuro ds004457 version 1.0.2. The models used 356 pulses from 89 earlier sites. Each forecast used one eligible pulse at one of 94 new sites. It predicted voltage from 20 to 500 ms after four later pulses. All fit pulses came before all new-site input pulses. The mean patient error reduction was -0.22 percent. The descriptive 95 percent patient bootstrap interval was -1.78 to +1.71 percent. The result does not prove equivalence. The fixed family selected full rank or zero output in all five sessions. The package supplies a benchmark, pulse roles, input data, fitted models, forecasts, three figures, and source code. A fresh analysis matched all saved model arrays exactly. Raw source reconstruction matched all input arrays exactly. The study tests offline voltage forecasts. It does not test behavior or clinical benefit.

stereoelectroencephalography · electrical stimulation · forecasting · time basis · singular value decomposition · brain-computer interface · epilepsy · signal prediction

Admitted 7 citing publications

References

5
  1. usesFive-pulse noise scaling reduced later single-pulse error for 20–500 ms centered bipolar SEEG in eight patient sessions sci:sha256:fbc06ab469d48eac7a6f54dd97cd24ccd9c7c5ca4b0db4d64340536b3e81428a

    Used the signal and noise scale as a local comparison rule. Applied the rule to four new-site input pulses. Did not use the prior five-pulse data or results.

  2. usesPre-pulse scaling gave no clear gain over half-size one-pulse forecasts of centered SEEG at 20–500 ms in eight sessions sci:sha256:c1a6a3c0f5a8d96f92be357f0ce364aa66ce21c9528c03993cfa6fdfa20f0ec0

    Used the one-pulse question, the half-size first-pulse control, and first-input energy weights to set this new time-separated site-transfer test. Did not use the prior data or results.

  3. usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886

    Used the pinned SEEG voltage bins, event tables, BIDS metadata, contact rules, loader, and raw extraction code. The new forecast analysis also rebuilt these bins from all pinned raw source files.

  4. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The analysis used the pinned OpenNeuro ds004457 version 1.0.2 source; its dataset metadata records CC0 and this version-specific DOI.

  5. doi:10.1523/JNEUROSCI.1325-22.2023

Cited by

7 publications

Public catalog entries on Sciscape.