A fixed one-pair model raised mean relative error by 12.4% for later five-pulse SEEG forecasts in seven people
We tested whether one recorded SEEG pair could forecast other pairs after a change of stimulation site. We used public OpenNeuro ds004696, version 1.0.1. A fixed linear model used first-five pulse means from earlier sites. At each later site, it read the first five pulses at one pair. It predicted the final-five mean at pairs with no shared contact. The test included seven people, 31 later sites, and 306 site-output pairs. Mean person-level relative error was 12.4% higher than the earlier-site mean. Five of seven people had higher error. The planned benefit and before-pulse control tests did not show success. Direct first-five output measurement gave lower error than the spatial model in all seven people. These results apply to this fixed model and five-pulse means at 256 Hz. They do not establish failure of all spatial models or safe brain control. The package preserves compact data, four figures, code, a fixed analysis plan, source hashes, and a retrieval recipe. Fresh source checks rebuilt 190 mean traces for 95 site-output pairs with no numeric difference.
SEEG · electrical stimulation · spatial forecasting · intracranial EEG · forecast error · five-pulse mean · limbic system
References
6- usesSeparate five-pulse profiles had higher mean SEEG spatial error than a shared profile at 20–500 ms in seven patient sessions sci:sha256:5964333645182e3e091ae0b0e203243c3115e3e8a570821a583d82640f2a56e4
The shared spatial profile result informed the question. This test uses time-ordered training sites, waveform error, and one measured pair at each new site. It does not retest the earlier energy-profile claim.
- usesFive-pulse noise scaling reduced later single-pulse error for 20–500 ms centered bipolar SEEG in eight patient sessions sci:sha256:fbc06ab469d48eac7a6f54dd97cd24ccd9c7c5ca4b0db4d64340536b3e81428a
This study uses the archived first-five and final-five mean SEEG traces, edge tables, and site tables. It checks all parent file hashes. It tests spatial transfer across later stimulation sites at the archived 256 Hz rate.
- usesA learned time basis did not show lower mean one-pulse SEEG forecast error at 94 new sites in five patient sessions sci:sha256:7aa30d9799432d4754152e931d764d9f390ea9b971b9c6e176501180aabbeebf
The earlier time-basis test informed the site-transfer question. This study tests a spatial map across recording pairs in another public SEEG dataset. It uses no data from the time-basis study.
- usesPast pulse updates reduced normalized 20–500 ms SEEG forecast error versus fixed five-pulse templates at 86 selected sites in eight epilepsy sessions sci:sha256:fd07147e53abc31f50ad87cee1d777a9d91b45b3d2a172703485899005f00530
This study uses the pinned OpenNeuro source records, clinical metadata, upstream preprocessing records, and GPL download code. Fresh source checks rebuild 190 mean traces for 95 site-output pairs.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
Source dataset for the analyzed first-five and final-five SEEG means; the cached exact-version metadata records CC0.