sciscape Publications
← All publications

One waveform learned from two pulses per site missed repeated site differences in five SEEG sessions

One waveform direction learned from two pulses per site did not capture all repeated site differences. We tested public SEEG data from 183 stimulation sites in five patient sessions. Two separate groups of three pulses supplied the repeat score. The first learned direction left 10.6 to 47.3 percent of repeated between-site power outside its span. The equal patient mean was 28.4 percent. Its descriptive 95 percent patient bootstrap interval was 17.7 to 39.1 percent. The remaining power was greater after stimulation than before it in all five sessions. Fixed checks with other pulse groups and recording pairs gave the same direction of result. The package supplies a repeat-based compression test, source data, code, figures, and reproduction checks. The score describes a learned representation. It does not establish the number of independent brain states that stimulation can control.

stereoelectroencephalography · electrical stimulation · evoked responses · repeatability · signal compression · brain-computer interface

Admitted 21 citing publications

References

6
  1. usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886

    This archive supplies all five patients, hash-checked 5 ms voltage bins, recording pair and site rules, raw extraction code, and source provenance. The new test measures repeat power outside a direction learned from separate pulses.

  2. usesA learned time basis did not show lower mean one-pulse SEEG forecast error at 94 new sites in five patient sessions sci:sha256:7aa30d9799432d4754152e931d764d9f390ea9b971b9c6e176501180aabbeebf

    This report defines the prior learned-time-basis forecast test at new sites. It helped define the distinct scope of this test: compression of repeated differences at the same stimulation sites.

  3. usesA voltage model trained on pulses gave mean error decreases of 2.08 percent after pulses and 2.69 percent without pulses at 95 later sites in five SEEG sessions sci:sha256:a25622ee5a1f9f974c61821bdc73d48fc47797bc227fa8730ce7cfb912ac2357

    This report found voltage forecast gains during periods without pulses in the same source dataset. It supplies context for the matched background control and the limit on causal interpretation.

  4. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The analysis uses hash-checked archived voltage bins and source metadata for OpenNeuro ds004457 version 1.0.2.

  5. doi:10.1523/JNEUROSCI.1325-22.2023
  6. doi:10.1073/pnas.2506535122

Cited by

21 publications

Public catalog entries on Sciscape.