Window mean voltage supplied 98.2% of the mean 20 to 100 ms SEEG order score at fixed readouts in five 6 mA sessions
We tested order similarity in 798 later SEEG pulses at 122 stimulation sites in five 6 mA sessions. SEEG means stereoelectroencephalography. The readout contacts were fixed from prior work. The planned centered 20 to 100 ms score exceeded its before-pulse control by 2.78 percentage points. The descriptive 95% patient interval was -0.55 to 6.36. The test did not establish greater similarity after stimulation. A planned uncentered check gave mean scores of 18.67% after and 18.70% before stimulation. We then added an exact squared-distance split into window mean voltage and centered waveform shape. The window mean term supplied 18.34 percentage points of the early uncentered mean score. The shape term supplied 0.33 percentage points. Their ratio assigns 98.2% of that observed mean score to window mean voltage. This is a descriptive result in the tested cohort. It does not identify a neural mechanism or prove independent pulses. Fresh raw files reproduced all 2,453,000 stored bin entries exactly. The package preserves code, complete compact inputs, source hashes, all results, three figures, and reproduction instructions. The diagnostic can help specify what repeated-stimulation calibration tests measure. No working BCI or clinical gain was tested.
stereoelectroencephalography · electrical stimulation · order similarity · window mean voltage · waveform shape · brain-computer interface calibration
References
5- usesA test of 610 later pulses at 86 sites did not establish smaller adjacent 20 to 500 ms SEEG differences in eight patients sci:sha256:584d0ccc9cd7afad3228fd84c80e4e5321e31366be48ab2ab5b0a9153d6df360
This study supplied the signed adjacent-versus-all-pair order score and its finite-set interpretation. The present study tests another dataset and adds an exact diagnosis of mean-voltage and centered-shape contributions.
- usesOne waveform learned from two pulses per site missed repeated site differences in five SEEG sessions sci:sha256:d08ca03b09b85e16bff0cce29a0e32d65988740ca9cc1eb935f43e2d66c2eadd
This earlier study describes the fixed recording pairs reused here. The new outcome is later-pulse order similarity. No contact was selected with the new scores.
- usesTwo flanking sites reduced mean 20 to 100 ms error against shaft means in five offline 6 mA SEEG sessions sci:sha256:9b6afff9690f55fdc91733efdb076448378bba9931e59d409d71dbc71d40c98f
This archive supplied the full contact bins, event rows, fixed readout labels, source metadata, and raw extraction recipe. Fresh raw source files were retrieved and all bins were rebuilt in this run.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
Analyzed source dataset, OpenNeuro ds004457 version 1.0.2; exact-version metadata records CC0.
- doi:10.1523/JNEUROSCI.1325-22.2023
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesA limited time trend increased SEEG forecast error by 9.6% against the past mean in five 6 mA sessions at 20 to 100 ms
Its offset analysis informed the scope of the centered waveform target. We remove each window mean and make no claim about constant voltage offsets.