Full covariance did not establish a mean increase in SEEG response spread at 20 to 100 ms in five sessions under stable means and independent errors with zero mean
We compared response spread in two calibration noise metrics with public SEEG data from five patients. The main test used 138 remote stimulation sites, 15 bipolar recording pairs, and 1104 pulses. Four early pulses per site fitted the metrics. Four separate late pulses gave response moments at 20 to 100 ms. The full metric was C = 0.5 S + 0.5 D; the diagonal metric was D. The moment estimates are unbiased conditional on calibration under stable site means and independent late errors with expected value zero. The ratios can be biased. The mean full-minus-diagonal change in spread f was -0.0445. A descriptive interval from five patient point estimates was -0.1299 to +0.0299. The exact sign p value was 0.4375 under symmetric independent patient differences. The data did not establish a mean increase. They did not establish equivalence. In patient 5, spread fell while site accuracy increased by 9.375 percentage points. The late window and broader site set changed the sign of the mean spread effect. An invertible metric changes participation ratio while preserving response rank. Spread is thus a separate outcome from site reading and brain control. The package includes the conditional proof, voltage bins, source hashes and retrieval recipe, fitted states, predictions, tables, and three figures. Fresh raw extraction reproduced 30 input arrays and five event tables. A full replay reproduced 53 result files byte for byte. This is an exploratory extension on reused data. It does not establish live interface performance.
stereoelectroencephalography · SEEG · response spread · participation ratio · noise covariance · brain-computer interface · neural stimulation
References
6- usesFour pulse groups gave SEEG response participation ratios of 1.20 to 2.80 in five sessions under stable means and independent errors with zero mean sci:sha256:0de878dd8b3be59a676a1baeec5435df4e50ef630d6431b79cda498a7ccbec96
Used its four-independent-group moment construction and negative-moment rule. Extended the target to condition on an early fitted metric, with four separate single late pulses as the moment replicates. Preserved the stable-mean and independent-error assumptions.
- usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886
Used its fixed covariance comparator C = 0.5 S + 0.5 D and diagonal comparator. Applied both metrics to separate late-pulse response moments rather than treating site accuracy as a spread measure.
- usesOne waveform learned from two pulses per site missed repeated site differences in five SEEG sessions sci:sha256:d08ca03b09b85e16bff0cce29a0e32d65988740ca9cc1eb935f43e2d66c2eadd
Used the upstream pinned input provenance and good-contact cohort rules received through b2613210. Preserved its MIT code notice and checked the input hashes. The same source sessions were reused.
- usesLate SEEG features gave no clear accuracy gain at eight values per pair in five offline sessions sci:sha256:ed40fd0a8b5470426e0359f53813cbbbe8618e7309c70555d486ca08432b065b
Used its archived voltage bins, event tables, BIDS metadata, source manifests, and extraction and cohort code. Kept its remote-shaft 6 mA sites and first-four/last-four pulse allocation for the new response moment comparison.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
The analyzed source is OpenNeuro ds004457 version 1.0.2; the publication records its fixed Git tree and source hashes.
- doi:10.1523/JNEUROSCI.1325-22.2023
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesMean voltage from four pulses at the same site gave 43.8% accuracy and label votes gave 40.1% at 20 to 100 ms in five offline SEEG sessions
This publication supplied the hash-verified contact voltage bins, event tables, BIDS metadata, retrieval recipe, and extraction code. We rebuilt the raw public subset and checked exact equality before testing repeated-pulse aggregation.
- usesA 90% timing prior gave no clear accuracy gain over nine shifted SEEG templates in five offline sessions
This publication supplied the ten voltage-bin and event files, source metadata, and preserved extraction code. All input hashes matched. They enabled the fixed timing-prior test on the same five sessions.