A voltage model trained on pulses gave mean error decreases of 2.08 percent after pulses and 2.69 percent without pulses at 95 later sites in five SEEG sessions
We tested whether voltage before a pulse improves forecasts at later SEEG stimulation sites. OpenNeuro ds004457 v1.0.2 supplied nine bipolar readouts in five patient sessions. The model used eight voltage inputs. All model fitting and penalty selection preceded the later sites. Four eligible pulses set the mean at each new site. The last four pulses tested the 30 to 500 ms waveform. The test included 95 distinct later sites and 380 distinct test events. The patient mean error decrease was 2.08 percent relative to the four-pulse mean. One patient supplied 92.76 percent of the gain. The exact two-sided patient sign-flip value was p = 0.0625. A mean scaled for calibration noise had lower error than the voltage model in four of five patients. An exploratory control applied the unchanged pulse-trained coefficients to periods one second before each pulse. No pulse occurred in those target windows. This control gave a 2.69 percent mean error decrease, again with most gain in one patient. The result does not establish prediction of a change caused by stimulation. The package provides a chronological benchmark, input epochs, all forecasts, code, figures, source hashes, and raw retrieval steps. A fresh raw rebuild matched every stored epoch array. The scope is offline voltage in these five sessions.
SEEG · electrical stimulation · brain-computer interface · voltage forecasting · ridge regression · temporal generalization · no-pulse control · waveform prediction
References
6- usesFive-pulse noise scaling reduced later single-pulse error for 20–500 ms centered bipolar SEEG in eight patient sessions sci:sha256:fbc06ab469d48eac7a6f54dd97cd24ccd9c7c5ca4b0db4d64340536b3e81428a
This study adapts its calibration cross-energy noise-scale formula from five records to four records. The resulting mean control tests whether the voltage model improves on a mean corrected for calibration noise. Its earlier dataset results are not claimed as reproduced.
- usesThree early valid 6 mA pulses per site selected sites with greater later SEEG voltage energy than random expectation in five patient sessions sci:sha256:2986e9c79b14eb86379a6faea58142d182aaac35b734ad23f0dd1db049ae222a
This study uses its nine selected ventral temporal bipolar readouts, epoch arrays, fixed source manifests and metadata, and retrieval and extraction code. All nine epoch arrays were independently rebuilt from freshly downloaded raw files. The new work uses earlier-site model fitting, later-site waveform tests, and no-pulse controls.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
The analysis used nine bipolar readouts from ds004457 v1.0.2; the package records the fixed Git commit and source-file hashes.
- usesdoi:10.1523/JNEUROSCI.1325-22.2023
This is the source study for the stimulation recordings analyzed here.
- doi:10.1111/epi.17528
- doi:10.1101/2025.09.18.677069
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesOne waveform learned from two pulses per site missed repeated site differences in five SEEG sessions
This report found voltage forecast gains during periods without pulses in the same source dataset. It supplies context for the matched background control and the limit on causal interpretation.