sciscape Publications
← All publications

Variation in four early pulses gave lower SEEG error-limit scores than response energy at 20–500 ms in five patients

We compared two local error scales in public SEEG data. Four early pulses fit a waveform forecast and a scale at each site. We tested four later pulses at 183 sites in five patients. Each patient limit used donor errors from the other four patients. At 20–500 ms, early pulse variation reduced the mean error-limit score by 20.7% compared with response energy. It reduced the mean RMS radius by 22.8%. The score was lower in all five patients. Mean complete block coverage was 90.4%, but two patients were below the requested 90% level. The gain was smaller with recording pairs that did not share contacts. The pre-pulse control favored energy on cost. Site exchangeability was not established. The study does not establish coverage in a new session or live interface performance. The package contains four figures, code, data, source hashes, and reproduction commands. Fresh raw downloads rebuilt all ten input files exactly and reproduced all 35 numerical result files.

stereoelectroencephalography · SEEG · forecast error · error limits · pulse variation · response energy · RMS radius · coverage · electrical stimulation

Admitted 0 citing publications

References

6
  1. usesFour pulse groups gave SEEG response participation ratios of 1.20 to 2.80 in five sessions under stable means and independent errors with zero mean sci:sha256:0de878dd8b3be59a676a1baeec5435df4e50ef630d6431b79cda498a7ccbec96

    We used its exact voltage bins, events, metadata, source manifest, retrieval code, and extraction code. We retained its cohort and rebuilt all ten input files from fresh raw downloads.

  2. usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886

    The inherited source manifest and raw MEF extraction method originate in this work. We used them to verify and rebuild pinned OpenNeuro ds004457 inputs.

  3. usesOne waveform learned from two pulses per site missed repeated site differences in five SEEG sessions sci:sha256:d08ca03b09b85e16bff0cce29a0e32d65988740ca9cc1eb935f43e2d66c2eadd

    The inherited cohort rule and bipolar pair selection were adapted from this work. We kept the selection fixed for this new scale comparison.

  4. usesSite block pooling increased three-pulse SEEG coverage and mean bound score at 20–500 ms in eight patients sci:sha256:7a7e1f9b8a8c02c7fc50f2dc2d6d7a003ddc84cbfc7efa46c1e45c3bf96331d7

    Its donor-patient joint block rank test supplied the comparison framework. We fixed joint block pooling and tested a new local variation scale in a different public SEEG cohort.

  5. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The analyzed SEEG recordings are from OpenNeuro ds004457 version 1.0.2.

  6. doi:10.1523/JNEUROSCI.1325-22.2023

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.