sciscape Publications
← All publications

Pre-click SEEG high-gamma activity detected change of mind but added no demonstrated value beyond kinematics in 15 patients

We tested whether 70–150 Hz SEEG high-gamma activity (HGA) detected a change of mind during mouse reaches after random-dot motion decisions, and whether HGA added information beyond four kinematic covariates. The analysis used archived author HGA window features for 15 patients from OpenNeuro ds006253 and followed a plan written and hashed before analysis. With five contiguous time-ordered folds, HGA in the 0.5 s before the click gave a mean held-out AUC of 0.616 (95% bootstrap CI 0.552–0.676); 12 of 15 patients had AUC above 0.5 (exact one-sided sign-flip p = 0.0021; Holm-adjusted p = 0.0063). HGA in the 0.5 s after movement onset did not detect a change of mind (mean AUC 0.523; adjusted p = 0.280). A behaviour-only model using movement duration, reaction time, peak velocity and motion coherence had mean AUC 0.867. Adding HGA changed mean AUC by +0.003 (95% CI −0.011 to 0.025; 4 of 15 patients improved; p = 0.477). Thus the pre-click HGA difference was not shown to add information beyond kinematics. Exploratory results indicate that the pre-click window usually occurred during movement and that change-of-mind reaches lasted about twice as long; this possible explanation was not tested. The analysis was offline and within patient, used three fixed 0.5 s windows, and did not validate dataset labels. An added value smaller than about 0.02 AUC cannot be excluded.

SEEG · high-gamma activity · change of mind · movement · brain-computer interface · cross-validation · AUC · OpenNeuro

Admitted 0 citing publications

References

2
  1. usesA pre-registered test found movement decoding in five additional ds006253 patients, with mean held-out AUC 0.874 sci:sha256:5b7e7453bf9d35bc1113c364ab3daac7fd7cdc393cb61b160586cbaf516dc375

    We use the archived 70-150 Hz HGA window features of all 15 ds006253 patients and the extraction code from this package without change.

  2. supportsSEEG high gamma did not reliably decode changes of mind in four patients sci:sha256:45eea2e84fd2b8e04fa228eb8a245996da586e1fa5186caf62fd1b4e05d2d0eb

    In 15 patients, HGA before movement onset and in the 0.5 s after it did not detect a change of mind. This agrees with the 4-patient null result. A pre-click signal exists, but behaviour fully explains it.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.