sciscape Publications
← All publications

A distance model gave 1.1% higher mean relative 20–100 ms SEEG response error on whole held-out shafts in four patients

We tested whether anatomical distance can reduce stimulation calibration at a new electrode shaft. We used public SEEG data from OpenNeuro ds004457 version 1.0.2. The fixed metadata rules left 115 sites on 28 shafts in four patients with epilepsy. A fifth patient had only two eligible shafts and was excluded by the fixed three-shaft rule. Ten fixed bipolar pairs measured the responses. Each outer fold removed all signals from one stimulation shaft during fitting and parameter selection. Inner shaft folds selected a Gaussian distance width and a weight on the global mean. Calibration used the first four good 6 mA pulses at each donor site. Testing used the final four pulses at each target site. The primary endpoint was mean squared centered voltage error from 20 to 100 ms. The distance model gave 1.05% higher mean relative error than the global mean response. The descriptive patient bootstrap interval for error reduction was -4.60% to 1.89%. Four local target pulses gave 81.47% lower error. A time model gave 1.59% higher error. A fixed check with recording pairs that share no contact gave 3.13% lower distance error. Thus the result depends on the recording set. It does not show that distance cannot help in general. The package preserves input bins, source metadata, a dated plan, complete folds, predictions, figures, code, and a pinned raw retrieval recipe. Independent error checks, held-shaft signal replacement, a full repeat run, and raw reconstruction were used for verification. The study is an offline test in four sessions. It does not establish a prospective controller or a perceptual effect.

stereoelectroencephalography · electrical stimulation · response prediction · anatomical distance · calibration · whole-shaft validation

Admitted 2 citing publications

References

5
  1. usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886

    This work supplies the exact preserved contact bins, source event tables, fixed ventral temporal contact list, pinned source file manifest, and raw extraction method used for this whole-shaft response test.

  2. usesNeighboring stimulation pairs reduced offline SEEG prediction error in five patients, but site order confounded spatial transfer sci:sha256:33c33a6543262722110a335be73c9a8ad8d047a9d5831868e69c8fc52b59516b

    Its adjacent-site prediction result and acquisition-time confound motivated a different test that excludes whole stimulation shafts and compares anatomical distance with acquisition time. The present analysis uses the same source cohort and does not refute the earlier neighbor result.

  3. usesA fixed average of local and earlier neighbor pulses increased 20–100 ms SEEG forecast error in three of five sessions sci:sha256:891c5fbfe0d5c4f527464a69406ad8958ba49058600af01846ffec1f0f8cc590

    Its early response forecast result informed the comparison with direct local calibration. This work tests zero-target-calibration transfer across whole shafts rather than a mean of one local pulse and one earlier neighbor pulse.

  4. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The analysis uses the pinned contact bins, event tables, electrode metadata, and source recordings from OpenNeuro ds004457 version 1.0.2.

  5. usesdoi:10.1523/JNEUROSCI.1325-22.2023

    Huang and colleagues report the source cohort and electrical stimulation recordings used by this analysis.

Cited by

2 publications

Public catalog entries on Sciscape.