A fixed four-contact model gave 1.5% higher mean 20–100 ms SEEG power forecast error at excluded recording shafts in eight patients
In a fixed benchmark using 96 stimulation conditions from eight patients with epilepsy, a four-contact geometry term produced 1.50% higher equal-patient mean forecast error than a reduced model for 20–100 ms pulse-associated SEEG power at recording shafts excluded from calibration. The mean squared error was 1.119117 with the added term and 1.102584 with the reduced model; the difference was 0.016533. Error was higher in six patients and lower in two. A descriptive 95% patient bootstrap interval for the difference was 0.000332 to 0.034985, while the two-sided sign-flip reference was 0.1172 across all 256 patient sign patterns. With eight patient units, these summaries do not establish a population increase in error or equivalence. Across the fixed checks, the mean result depended on penalty and outcome definition. The study used a previously studied sample, and its target was total measured pulse-associated power, not isolated neural response power. The test does not establish transfer to a new patient, an unmeasured stimulation site, or clinical benefit.
stereoelectroencephalography · SEEG · forecasting · electrode geometry · ridge regression · brain-computer interface · epilepsy
References
7- usesFixed distance weights gave 1.6% higher mean relative SEEG power error at excluded shafts in eight patients sci:sha256:1c6b8bcedc82cbb2a0fde7f22417df13d8887c1f40cb02ef5595c33ded818472
Its spatial transfer test with fixed distance weights in STReEF helped define the question. The present test changes the excluded signals to complete recording shafts and compares a new four-contact term.
- usesGreater distance was associated with a smaller early window advantage in repeatable SEEG voltage at 96 conditions in eight patients sci:sha256:8ce49df0e874a8fe67c61d4467b06d1a1564be89d2f8ec47da539373586edbd8
This publication supplied the fixed 96-condition sample, verified waveform products, matched before-pulse products, raw source pins, metadata, and retrieval code. These files enabled the new excluded-recording-shaft forecast test.
- usesA distance model gave 1.1% higher mean relative 20–100 ms SEEG response error on whole held-out shafts in four patients sci:sha256:3fbd86d170791ec558aac48a20c3a85564ceaa3620c40f9ad4078a56895accfc
Its distance model test on excluded stimulation shafts helped define the spatial transfer question. The present test uses a different public cohort and excludes recording shafts. The numerical scores are not direct comparisons.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
The analysis used STReEF, OpenNeuro ds005448 version 1.0.0; the source URL, release commit, and retained input hashes identify the analyzed files.
- doi:10.1016/j.ynirp.2025.100274
- doi:10.1007/s12021-022-09567-6
- supportsdoi:10.1007/s10827-009-0205-z
This source supports the report statement that tissue structure can affect intracranial field prediction; its during-pulse experiment differs from this delayed-power forecast.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesContact exclusion raised fixed 20–100 ms SEEG power forecast error by a mean 22.7% across eight patients
This work uses the compact pulse powers, native coordinates, selected events, source metadata, and pinned raw retrieval code. This run checked all 960 raw ranges and all 408,180 window powers against that input. The new analysis adds test contact exclusion and an exact donor count control.