A fixed adaptive gradient rule showed no clear 20–500 ms SEEG forecast gain in eight sessions
A BCI response model must balance older pulse data with recent pulse data. We tested one fixed adaptive gradient rule on OpenNeuro ds004696 SEEG data from eight epilepsy sessions. The test used 86 fixed readouts, five calibration pulses per readout, and 610 later target pulses. The rule blended scaled all-history and recent-five means. Its mean person gain against all history was 0.06894%; the 95% person bootstrap interval was −0.99795% to 1.40769%. Two of eight people improved. Mean normalized loss was 0.35232 for the adaptive rule and 0.35102 for all history. A fixed blend selected after all targets gave a 2.24% mean person gain, but requires future data. All 86 sites met the deterministic accumulated-error bound. These exploratory results establish neither a gain nor equivalence between methods. The cohort is reused; the analysis does not establish BCI safety or clinical benefit.
SEEG · brain-computer interface · adaptive gradient · forecasting · electrical stimulation · regret bound · calibration
References
4- usesAt rate 1, learned weights reduced 20 to 500 ms SEEG forecast error against equal weights but raised error against scaled means in eight recordings sci:sha256:ef0c0959114fb72eaef63b2306de27883d737af4882e1642fc43cc265cd97c7b
Its four-expert weight result motivated the strong scaled all-history comparator. We tested a continuous two-forecast blend with a different update rule and readout set.
- usesPast pulse updates reduced normalized 20–500 ms SEEG forecast error versus fixed five-pulse templates at 86 selected sites in eight epilepsy sessions sci:sha256:fd07147e53abc31f50ad87cee1d777a9d91b45b3d2a172703485899005f00530
We used its full good-pulse waveforms, fixed early readout choices, source extraction code, and all-history baseline. These inputs made the causal blend test possible.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The compact input waveforms and pulse records are derived from OpenNeuro ds004696 version 1.0.1.
- usesdoi:10.1523/JNEUROSCI.2201-22.2023
This is the data authors’ source study for the processed SEEG derivatives and inherited readout choices used here.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesA variance rule showed no clear 20–500 ms SEEG forecast gain at an equal pulse budget in eight offline sessions
We used its 16 exact pulse data files, 86 fixed readouts, event metadata, and inherited complete-source checks. Its GPL source retrieval code enabled the new fresh checks. All compact inputs passed fresh service hash checks.