Mean late response map agreement over 35 pulse splits was lower than chronological agreement in five SEEG patients
We tested pulse split choice in public SEEG data from five patients in OpenNeuro ds004457 version 1.0.2. Each of 314 edges used its first eight eligible pulses at one constant current. We calculated response energy from 50 to 250 milliseconds. We compared chronological halves with all 35 unordered partitions, using common pulse positions across each patient's edges. Mean Spearman agreement was 0.488 over the 35 splits and 0.516 for chronology. The mean difference was -0.028, with a descriptive 95 percent t interval from -0.074 to 0.019. The difference was positive in two patients and negative in three. The exact two-sided patient sign-flip value was 0.25 under independence and null symmetry. The result does not support a consistent increase from random position splits. It does not prove equivalence or identify a neural mechanism. This is a secondary analysis of the parent clinical sample. The package preserves all maps, pulse selections, code, source hashes, results, and instructions. Independent calculations matched every main score. A fresh rebuild matched all 10,161,994 array elements from 54 public raw objects. A mathematical check gives the joint exchangeability condition for a zero expected split difference.
stereoelectroencephalography · electrical stimulation · pulse split · response map · rank agreement · reliability
References
5- usesThe variation fraction was higher at 50 to 250 ms than at 20 to 50 ms in eight-pulse SEEG maps from five patients sci:sha256:bd84aa2a00f16f6704a85755f643ec8bf720bc6ebdb7140beeb5facf814dc5bc
We used its calibrated epochs, eligible edge list, source tables, fixed raw object manifests, and extraction code. A fresh public source rebuild matched every preserved array element. The new pulse split analysis uses the same five patients.
- usesMean late response rank agreement decreased from 0.564 to 0.452 after sample variance subtraction in five selected SEEG patients sci:sha256:7f80f9660af79da244b497ffa94124fa1636e976fe409521f938472e9b739669
Its test of variance-corrected late response energy informed the fixed corrected-energy check. This prior work uses the same clinical sample and is not independent evidence for the new split result.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
This exact-version OpenNeuro dataset supplied the five-patient SEEG recordings analyzed here.
- doi:10.1523/JNEUROSCI.1325-22.2023
- doi:10.1371/journal.pcbi.1011105