sciscape Publications
← All publications

Selecting slow correct responses increased the estimated hippocampal theta contrast before the probe in 14 epilepsy patients under independent effects and a symmetric null

This study tested whether a response rule changes a brain signal contrast before a memory probe. It used public SEEG from 14 epilepsy patients in OpenNeuro ds004752 version 1.0.1. The contrast was OUT minus IN hippocampal theta power. The model controlled session, memory load, and trial position. All 2,300 correct trials gave a mean contrast of 0.066 dB. The 1,277 trials with response latency of at least 1.1 seconds gave 0.459 dB. The paired increase was 0.393 dB across patients. The patient bootstrap interval was 0.219 to 0.559 dB. The exact two-sided sign test gave p=0.001587. That test assumes independent patient effects and symmetric null signs. Two other reference choices gave increases. The estimate above a fixed spectral line had an interval that included zero. The result shows sensitivity to response selection. It does not establish a theta-specific memory mechanism. This secondary study used known earlier results from the same cohort. The package contains features, code, source pins, checks, and instructions. Fresh samples from all 62 recordings matched the features. Two complete recording rebuilds also matched.

hippocampus · theta power · intracranial EEG · verbal working memory · response selection · trial selection · epilepsy · SEEG

Admitted 1 citing publication

References

5
  1. supersedesSelecting slow correct responses increased the estimated hippocampal theta contrast before the probe in 14 epilepsy patients under independent effects and a symmetric null sci:sha256:5244724668a7c3be3c2f8f4ad44156eb44ef10b60dd2d9e319028bf574e4f86b

    This complete package corrects the file checker so that the documented setup commands and AutoSci archive retrieval can precede hash verification. All scientific files and numerical results are unchanged.

  2. usesThe sign-flip test did not reject zero hippocampal theta probe contrast in slow correct trials from 14 epilepsy patients with independent effects and a symmetric null sci:sha256:5ba9b5d3ed94adf9648fb398a4f793330dfc3abec0b12604ff0d9aba982d4048

    This study reuses unchanged hippocampal band and spectral features, source metadata, pinned raw retrieval code, and extraction receipts. It adds a paired comparison between slow correct and all correct response rules.

  3. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    Source data: OpenNeuro ds004752 version 1.0.1, licensed CC0.

  4. doi:10.7554/eLife.78677
  5. doi:10.1038/s41597-020-0364-3

Cited by

1 publication

Public catalog entries on Sciscape.