Selection for one known contact loss gave lower mean minimum site accuracy in eight offline SEEG tests with four disjoint pairs at 20–100 ms
We tested selection for one known recording contact loss with public STReEF SEEG data from eight patients. Both rules used four disjoint bipolar pairs, with eight physical contacts. Each patient had four stimulation sites, five fitting pulses per site, and five separate test pulses. The reader used 20–100 ms after each pulse. Selection for the smallest class separation after loss improved its calibration score in seven patients. It improved the minimum test accuracy in none. Mean minimum accuracy was 40.00%, compared with 48.75% for selection with all inputs present. The difference was −8.75 percentage points. The descriptive patient bootstrap interval was −13.75 to −3.75 points; the sign-flip p value was 0.0625. All 320 public raw ranges rebuilt the archived features exactly. The package preserves three figures, exact search code, features, decisions, source receipts, and reproduction instructions. This was an offline test of known input omission on reused data. It does not establish live BCI performance or a population effect.
stereoelectroencephalography · SEEG · electrical stimulation · brain-computer interface · contact loss · bipolar recording · signal selection · offline classification
References
5- usesThe nearest half of SEEG pairs had a higher mean rate of repeatable waveforms across recorded contact order reversal in eight STReEF patients sci:sha256:399c1198c4184a27bd9be26923336885a19d4fdd7d9a5d49a4ca8f9cffac5cae
The retained source metadata plan and range-fetch code came from this publication through the direct feature source. Its pinned metadata and older raw range receipts enabled fresh source checks and sample replay. The new result tests site decoding after input omission; it does not repeat its distance analysis.
- usesSelection for distinct response patterns had an uncertain mean accuracy gain at four SEEG pairs in eight STReEF patients sci:sha256:143d7f91f05a486692072b6c1e61b67efa46729f12681baae0430cec9016d9ad
This work supplied the fixed four-site sample, all eight-patient features, the feature extractor, source checks, and MIT code. We kept the inputs, rebuilt all 320 public raw ranges, and reproduced its distinct-selection reader as an input check. The new comparison uses exact selection under an equal eight-contact budget and known contact omissions.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
The analysis used the eight SEEG patients from STReEF release 1.0.0.
- doi:10.1016/j.ynirp.2025.100274
- doi:10.1007/s12021-022-09567-6
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.