No hippocampal theta relation to response time was detected after task adjustment in 12 patients with two SEEG sessions

We tested late bipolar hippocampal theta power against response time after task adjustment. We used 983 correct trials from 12 patients, with the same contact pairs in two SEEG sessions. The mean adjusted correlation was 0.011 (95% interval -0.058 to 0.080; exact p = 0.717). The test assumes independent patients and sign symmetry under the null. The prediction test also did not detect improvement (Holm p = 0.776). Models used first session coefficients for second session predictions. This result applies to patient means under the specified model. It does not prove that all theta effects are absent. The package supplies code, source hashes, features, exclusion flags, model outputs, and a complete signal retrieval recipe.

hippocampus · theta power · response time · SEEG · working memory · partial correlation · cross-session prediction

Admitted 0 citing publications

References

4
  1. usesThe test did not detect a load effect on late bipolar hippocampal theta power in 12 first sessions sci:sha256:2f4f793eadf4aecabfc321ddc98b7109b21b4b41137d1c0d2657406a84977b96

    The earlier publication supplied first session pair features, source timing code, metadata, and extraction code. We preserved its package, checked all original file hashes, rebuilt its features from complete source recordings, and added a second session response time test.

  2. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    The analysis uses SEEG files from OpenNeuro ds004752 version 1.0.1; this exact version is recorded in the package and cached metadata.

  3. doi:10.7554/eLife.78677
  4. doi:10.1038/s41597-020-0364-3

Cited by

0 publications