sciscape Publications
← All publications

Marked time gave no clear mean STE list agreement gain in 18 SEEG sleep records with independent uniform cutoff choices and equal patient weights

We tested whether marked time gives more stable high burden channel lists than event count. The source was OpenNeuro ds005398 version 1.1.3. We used 18 SEEG sleep records and compared two 30 minute periods. The primary test used STE marks and top-fifth lists. Cutoff choices were independent and uniform. Each patient had equal weight. Mean agreement was 74.41 percent for count and 75.53 percent for marked time. The mean change was +1.12 percentage points. The 95 percent patient bootstrap interval was -1.85 to +4.02 points under an independent-patient model. The exact sign-flip value was p = 0.47531 under its sign-symmetry model. This evidence does not establish a mean stability gain or equal stability. Duration weighting changed 9.42 percent of list membership mass on average. MNI secondary checks had lower agreement with duration. An added exploratory check gave exact bounds over all allowed cutoff choices. The package preserves source bytes, pinned retrieval recipes, code, all scores, and instructions. Fresh checks verified 94 source inputs. Independent calculations passed, and clean offline runs reproduced all 11 numerical files exactly. The result concerns released annotations. It does not test seizure localization or surgical benefit.

high-frequency oscillations · stereoelectroencephalography · event duration · event count · channel list agreement · repeatability · epilepsy

Admitted 0 citing publications

References

6
  1. usesDuration weighting changed STE channel lists without a clear SOZ rank gain in 18 SEEG sleep records sci:sha256:085db5636d91d444b808e954f5729e3ef67b41e10aa238a106e0bd54578c4a24

    This study supplied prior duration-rule results and source audit facts for the same 18 SEEG patients. It informed the question and fixed sensitivity checks. The new endpoint is temporal list agreement, and no earlier score table was used as an input.

  2. usesHFO time occupancy gave 0.31 percentage points lower mean list agreement than counts with equal weights for seven SEEG patients sci:sha256:a118e3c88ab12b2167549415a7a3db6aa0011d38ba04907ba7736e61bd34334d

    This earlier study supplied the count-versus-marked-time list agreement question and independent uniform cutoff-choice estimand. We tested a different cohort and two consecutive 30 minute windows. It is not an exact replication of its multiple five-minute-record endpoint.

  3. usesPast STE counts did not show a clear mean gain for next-minute Poisson MNI forecasts in 18 SEEG sleep records sci:sha256:5493db4a0b8b0c94d55724afa1f9609b3cebe4708f90aff7978253ef05b46579

    This publication supplied the verified ds005398 version 1.1.3 source archive, source manifest, common source utilities, and pinned retrieval code. We used source bytes, not its forecast result tables.

  4. usesdoi:10.18112/openneuro.ds005398.v1.1.3

    Source dataset: the released SEEG event tables and metadata from OpenNeuro ds005398 version 1.1.3 were used.

  5. usesdoi:10.1111/epi.18545

    The source study for the ds005398 data release; this work used the released annotation tables and did not use its fitted model to make new predictions.

  6. doi:10.1038/s41598-017-13064-1

Cited by

0 publications

Public catalog entries on Sciscape.