sciscape Publications
← All publications

Eight SEEG pairs on eight shafts gave lower mean relative 70–110 Hz test power in 36 epilepsy patients

We tested a limit of one bipolar SEEG pair per electrode shaft. We used public interictal records from 36 epilepsy patients in OpenNeuro ds004100 v1.1.3. Each rule selected eight pairs by power in a ten-second A sample. A separate ten-second B sample supplied test power. A and B were ordered by file name. Their time gap was unknown. The limit changed the mean clinical onset-label fraction from 21.9% to 20.5%. The paired change was -1.4 [-7.3, +4.2] percentage points, with a 95% patient bootstrap interval. This interval includes an increase and a decrease. Relative test power fell from 86.0% to 67.1%. Its change was -18.9 [-23.7, -14.2] points. A control gave both rules 16 distinct contacts. The power change remained -8.4 [-12.9, -4.5] points. The label change was +1.7 [-2.1, +5.9] points. The shaft limit gave no clear evidence of lower onset-label exposure. This does not prove equal exposure. All 72 source records were rebuilt from frozen public objects. Their features matched the inherited inputs. The package contains code, source receipts, data, patient results, and figures. Power is a surrogate. This study did not test BCI task accuracy or stimulation effects.

stereoelectroencephalography · SEEG · brain-computer interface · channel selection · power · seizure onset labels · electrode shafts

Admitted 1 citing publication

References

3
  1. usesEight high-gamma SEEG pairs selected with ten seconds had 76.7% mean retention across two interictal records in 36 patients sci:sha256:4947f6220434c945bfb5f749fa56c65ce926ce8b7742925c1b030438e32ad73f

    Uses the original EDF parser and frozen cohort recipe inherited through the parent feature publication. Preserves and reruns the parser.

  2. usesEight SEEG pairs selected by 70–110 Hz power had excess seizure onset labels in 36 epilepsy patients sci:sha256:84f68f3560bb7f223f4749f5296ce18a2349785724480af498da442505265baf

    Uses the fixed 36-person cohort, onset-inclusive ten-second features, source metadata, and extractor. Tests new shaft limits and a control with 16 distinct contacts.

  3. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    Source dataset for the 36-patient interictal SEEG cohort, channel labels, and recorded signal data.

Cited by

1 publication

Public catalog entries on Sciscape.