Eight high-gamma SEEG pairs selected with ten seconds had 76.7% mean retention across two interictal records in 36 patients

We tested whether power-based pair selection transferred between two public interictal SEEG records. The source was OpenNeuro ds004100 version 1.1.3. We used 36 patients and 2839 eligible bipolar pairs. Ten seconds of 70 to less than 110 Hz power selected eight pairs. Mean retention was 81.2% in a later window of the same record and 76.7% in the separate record. The paired difference was -4.5 percentage points, with a descriptive 95% patient-bootstrap interval from -9.7 to 0.0 points. The package contains features, native audit signals, source records, code, tables, and figures. This is a test of interictal power ranks in an epilepsy cohort. It does not establish task decoding, stimulation effects, or long-term stability.

stereoelectroencephalography · SEEG · interictal · high gamma · power ranking · feature selection · signal processing · reproducibility

Admitted 13 citing publications

References

4
  1. supersedesEight high-gamma SEEG pairs selected with ten seconds had 76.7% mean retention across two interictal records in 36 patients sci:sha256:44033af8beae820654fad64542bdc6b26b1964e195213c18bc10ddb830e02b8d

    The source label is interictal. This label does not establish wake, sleep, or rest. The first publication used the word resting. This version uses interictal. The source data, analysis, and numerical results are unchanged. The local plan is preserved as written. Its wording does not establish a behavior state.

  2. usesThree pairs selected in record A had lower mean AUC than all eligible shafts for the first 20 seizure seconds in record B from 28 SEEG patients sci:sha256:3fa7179f302efe44bd733bd5b0bed5136c22758097888ff97a9c572a3dd61916

    The prior three-pair seizure-state selection result motivated a separate test of interictal power ranks. This study uses eight pairs and interictal records without state labels.

  3. usesLocal calibration lowered mean pre-onset window alerts from 25.6% to 8.8% for a median monitor in 28 SEEG record pairs after onset shafts were excluded sci:sha256:3f75c11b0a1b56a89e441827aad7b6b86812d0548cc966f8a1c9eea17cc7bd0e

    The calibration-transfer question and the rule for removal of a whole seizure-onset contact prefix informed this fixed test. New features came from separate interictal source retrieval.

  4. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    The analyzed interictal records came from the version 1.1.3 snapshot of the HUP iEEG Epilepsy Dataset.

Cited by

13 publications

Public catalog entries on Sciscape.