Three pairs selected in record A had lower mean AUC than all eligible shafts for the first 20 seizure seconds in record B from 28 SEEG patients
We tested whether three recording pairs selected from one seizure record could improve a brain-state reader in a separate record. We used 28 SEEG patient record pairs from OpenNeuro ds004100 version 1.1.3. The test used the first 20 seizure seconds and 50 pre-onset seconds. Mean AUC was 0.686 for the selected three-pair reader and 0.753 for a reader that used all eligible shafts outside the clinical onset shafts. The mean paired change was -0.068, with a 95% patient bootstrap interval of -0.112 to -0.022. The selected reader had lower AUC in 20 patients, higher AUC in seven, and the same AUC in one. Its advantage over random three-pair sets was uncertain. The reverse-record interval included zero. All 56 source records passed new bounded raw-signal checks. The package contains powers, source identities and byte-range hashes, code, saved models, window results, three figures, and commands to repeat the work. These reused retrospective event records do not establish daily alert rates, seizure prediction, or stimulation effects.
stereoelectroencephalography · seizure detection · brain-computer interface · signal processing · AUC · calibration transfer · intracranial EEG
References
3- usesLocal calibration lowered mean pre-onset window alerts from 25.6% to 8.8% for a median monitor in 28 SEEG record pairs after onset shafts were excluded sci:sha256:3f75c11b0a1b56a89e441827aad7b6b86812d0548cc966f8a1c9eea17cc7bd0e
Supplied patient and record selection, matched pair names, source channel and event tables, EDF identities and full hashes, and the all-shaft reader with separate fit intervals.
- usesThree-second averaging raises AUC for seizure windows 2 to 20 seconds after onset in 28 patients with SEEG recordings sci:sha256:82ac5acb29923b6b4fb81633d3ec2272a23fe8883ca4fa4faf58b8da4d7ffc40
Supplied the matched one-second band powers for 28 SEEG record pairs. The files were checked against its archive hashes. This study adds a fixed pair selection test.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Source dataset used for all 56 SEEG records; exact version and CC0 license are recorded in the importer metadata.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesEight high-gamma SEEG pairs selected with ten seconds had 76.7% mean retention across two interictal records in 36 patients
The prior three-pair seizure-state selection result motivated a separate test of resting power ranks. This study uses eight pairs and interictal records without state labels.
- usesEight high-gamma SEEG pairs selected with ten seconds had 76.7% mean retention across two interictal records in 36 patients
The prior three-pair seizure-state selection result motivated a separate test of interictal power ranks. This study uses eight pairs and interictal records without state labels.