sciscape Publications
← All publications

30 to 80 Hz bipolar slope maps retained mean correlation 0.841 after linear shaft trend removal in paired 60 s files from 33 SEEG patients

We tested bipolar slope maps in two public SEEG files per patient from OpenNeuro ds004100 version 1.1.3. The test used the first 60 seconds of each file and 33 eligible patients. The fit used 30 to 80 Hz, with 55 to 65 Hz removed. We selected 1,799 pairs without shared contacts. After removal of shaft means and linear contact-order terms, the mean patient correlation was 0.841. The patient bootstrap 95 percent interval was 0.804 to 0.877 under independent and exchangeable patient resampling. All 33 patients had positive correlations. All eight fixed descriptive checks also had positive scores in every patient. All 504 arrays rebuilt from 72 pinned raw excerpts matched exactly. The package preserves code, spectra, source versions and hashes, results, bootstrap draws, figures, and reproduction instructions. The files have unknown recording separation. Nonlinear anatomical and recording effects can remain. This result measures file agreement and does not establish a stable neural trait. This version adds the inherited source checksum list to package hash coverage. The scientific results are unchanged. The hash check allows local software and supplemental fetch metadata.

stereoelectroencephalography · spectral slope · bipolar derivation · map agreement · intracranial EEG · spatial trend removal

Admitted 0 citing publications

References

7
  1. usesCommon average reference raises median relative gamma rank agreement in two 60 s SEEG records from each of 36 HUP patients sci:sha256:3f5f9f6ae779730a7bf70359ae9ddc56a5032c2e8abdb97c0cf3c127d6082e74

    The fixed good-contact list and EDF reader came from this study. We preserved its reader and license through the direct source archive.

  2. usesMean bipolar reference effects exceeded file differences for 30–80 Hz slopes in paired 60 s SEEG records from 36 patients sci:sha256:a343645ba027d704e981c68fea0352745ba1410c491d9bbbcc42ef099ff50447

    We used the paired spectra, fixed contact list, extraction methods, and raw retrieval pins. We rebuilt all 504 spectrum arrays. We tested agreement after shaft trend removal.

  3. supersedes30 to 80 Hz bipolar slope maps retained mean correlation 0.841 after linear shaft trend removal in paired 60 s files from 33 SEEG patients sci:sha256:3e49c5e6eff3cffb3af7662b07cedd97a032e8e8ecc5199cf21adb686a4195ed

    The hash coverage program now allows the local software folder and supplemental AutoSci fetch metadata. All archived files remain covered. The scientific results are unchanged.

  4. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    Analyzed two public interictal files per patient from this exact dataset version; the package records its CC0 license.

  5. doi:10.1523/ENEURO.0492-21.2022
  6. doi:10.1088/1741-2552%2Fae1b3b
  7. doi:10.1038/s41593-020-00744-x

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.