Across 253 SEEG patients, beta peak frequency did not track alpha peak frequency as a 2:1 harmonic
We tested whether 14–30 Hz (beta) spectral peaks in bipolar SEEG track 7–13 Hz (alpha) peaks as a 2:1 harmonic should. A harmonic predicts increasing beta frequency as alpha frequency increases across pairs within a patient. We used archived 0.5 Hz spectra from 261 patients in OpenNeuro ds004789 (FR1, version 3.1.0) and ds004809 (catFR1, version 2.2.0), with one 60 s word-encoding segment per patient; 253 patients with at least 8 dual-peak pairs entered the primary test (21,997 pairs). Mean per-patient Spearman rho was −0.034 (95% CI −0.056 to −0.013; sign-flip p = 0.0033). The beta-on-alpha slope was −0.137 Hz/Hz (95% CI −0.193 to −0.083), excluding 2. Correlations remained negative after adjustment for MNI coordinates (−0.029; Holm p = 0.024) and within electrode shafts (−0.049; Holm p = 0.0005). The preregistered rule for a harmonic account was not met. A small 2:1 coincidence excess remained: 20.3% of pairs matched within 1 Hz, 2.3 percentage points above the within-patient shuffled baseline. Results were similar with a stricter beta threshold, at least 5 dual-peak pairs, and in FR1 alone; catFR1 alone had a negative estimate but was not significant (72 patients, p = 0.23). One planned alpha-height test was not estimable because 99.8% of pairs had a beta peak. Limits include one task epoch per patient, 0.5 Hz resolution, noisy peak frequencies, bipolar recordings, epilepsy patients, and RAM sites. The small negative correlations should not be interpreted as physiological anti-coupling; shared aperiodic fitting or band-edge peak detection may contribute. The test does not exclude harmonics in a small subset of pairs.
SEEG · neural oscillations · peak frequency · harmonics · spectral analysis · memory task · epilepsy
References
4- usesIn 247 RAM SEEG patients, alpha/theta ratios were enriched near 1.9–2.0, not specifically at 2:1 sci:sha256:f38b25dd219675a450bbc40fa950cafe59fbcb97f9786be44e4a307c7605d7d1
Uses its within-patient shuffle baseline for the 2:1 ratio. That work examined alpha/theta ratios. This work adds a frequency-tracking test for beta/alpha and finds that the 2:1 excess does not come with positive tracking.
- usesIn 261 RAM SEEG subjects aged 18–64, 4–13 Hz peak frequency did not decrease with age, while peak height and relative alpha power increased sci:sha256:0e36e73fa7707bba416e7d46869f09378b140e05e39d6e785874fd9baeda4c32
Input data: the archived 0.5 Hz SEEG spectra, electrode MNI coordinates, and the flatten() and peaks() code, used unchanged.
- usesdoi:10.18112/openneuro.ds004789.v3.1.0
The archived spectra used in this analysis include FR1 data from this recorded OpenNeuro version.
- usesdoi:10.18112/openneuro.ds004809.v2.2.0
The archived spectra used in this analysis include catFR1 data from this recorded OpenNeuro version.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.