In 247 RAM SEEG patients, alpha/theta ratios were enriched near 1.9–2.0, not specifically at 2:1
We tested whether theta and alpha peak frequencies in the same SEEG bipolar pair favor the golden-mean ratio 1.618 or the 2:1 harmonic ratio. We analyzed archived 0.5 Hz spectra from 261 patients and 28,461 pairs in the RAM FR1 and catFR1 memory tasks. In 247 patients with at least five dual-peak pairs, the mean within-patient enrichment was -0.0067 near 1.618 (95% CI -0.0131 to -0.0003; Holm p=0.044) and +0.0162 near 2.0 (95% CI +0.0075 to +0.0247; Holm p=0.0010). The enrichment scan peaked at 1.92, close to the median patient ratio of 1.91, and theta and alpha frequencies were positively correlated within patients (mean Spearman rho=+0.104). Thus, ratios near 2:1 were more common than predicted by a within-patient shuffle, but the result does not show a preference for exactly 2:1; the golden-mean prediction was not supported. Frequency correlation or harmonics of non-sinusoidal rhythms could explain the enrichment. The analysis used 60 seconds from the start of a memory task in epilepsy patients, without a rest condition, and spectra alone cannot distinguish harmonics from coupled rhythms.
intracranial EEG · SEEG · theta · alpha · beta · peak frequency · frequency ratio · harmonics · memory task · within-patient shuffle
References
3- usesIn 261 RAM SEEG subjects aged 18–64, 4–13 Hz peak frequency did not decrease with age, while peak height and relative alpha power increased sci:sha256:0e36e73fa7707bba416e7d46869f09378b140e05e39d6e785874fd9baeda4c32
The analysis uses the archived 0.5 Hz bipolar spectra of this work, verified by its SHA-256 sums, and reuses its aperiodic-line and peak method.
- usesdoi:10.18112/openneuro.ds004789.v3.1.0
The archived spectra include RAM FR1 data from OpenNeuro ds004789, version 3.1.0.
- usesdoi:10.18112/openneuro.ds004809.v2.2.0
The archived spectra include RAM catFR1 data from OpenNeuro ds004809, version 2.2.0.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesAcross 253 SEEG patients, beta peak frequency did not track alpha peak frequency as a 2:1 harmonic
Uses its within-patient shuffle baseline for the 2:1 ratio. That work examined alpha/theta ratios. This work adds a frequency-tracking test for beta/alpha and finds that the 2:1 excess does not come with positive tracking.
- supportsBeta peaks at twice alpha frequency show weak 1:2 phase locking in 70 RAM SEEG patients
Tests its open waveform limit: beta peaks at 2 x alpha show weak 1:2 phase locking, so a part of the 2:1 enrichment can be a harmonic of non-sinusoidal alpha.