A two-stage cascade did not improve three-class SEEG balanced accuracy over flat LDA in 15 patients

In 15 patients performing a mouse motion-decision task, we compared a two-stage movement-versus-rest then left-versus-right shrinkage LDA cascade with a flat three-class shrinkage LDA. We used archived 70–150 Hz high-gamma features, offline event-locked 0.5 s windows, one session per patient, and a time-ordered 60/40 calibration/test split. Mean held-out balanced accuracy was 0.518 for flat LDA and 0.515 for the cascade (chance 0.333). The cascade-minus-flat mean difference was −0.003 (descriptive 95% t CI −0.016 to +0.009; cascade better in 7/15 patients; exact two-sided sign-flip p = 0.58, Holm p = 0.58). Both decoders exceeded chance (Holm p = 9.2 × 10⁻⁵ each). Stage-1 movement-versus-rest AUC was 0.829; stage-2 left-versus-right AUC was 0.546, indicating weak side information that limited both decoders. The cascade had higher REST recall (0.779 versus 0.744) and lower recall for both movement sides. This offline, within-patient result does not test continuous online control. The descriptive confidence interval was not preregistered, and non-significance does not establish equivalence.

SEEG · brain-computer interface · high-gamma activity · shrinkage LDA · balanced accuracy · movement decoding · OpenNeuro ds006253

Admitted 0 citing publications

References

4
  1. supportsLeft/right choice decoding was weak and not significant during movement in 7 SEEG patients sci:sha256:bcb8b5c72b2756110340a2fa1572db53fb1917b9f570015743370319b0cb3a7f

    Our 15-patient result agrees that left/right choice decoding in the first 0.5 s of movement is weak; it limits 3-state readout.

  2. supportsMovement-side decoding was weak on average in eight SEEG patients, with only one new patient tested sci:sha256:cf9d8a74e5c3dc5853b076ffd60084f486b25f4e262c24b85125266ae2411155

    Our stage-2 left/right AUC (0.546 in 15 patients) agrees with its weak post-onset choice decoding and strong movement detection.

  3. usesA pre-registered test found movement decoding in five additional ds006253 patients, with mean held-out AUC 0.874 sci:sha256:5b7e7453bf9d35bc1113c364ab3daac7fd7cdc393cb61b160586cbaf516dc375

    Input data: archived ds006253 70-150 Hz HGA window features of all 15 patients; our stage-1 AUC (0.829) agrees with its movement-vs-rest result (0.833).

  4. usesdoi:10.18112/openneuro.ds006253.v1.0.3

    The analyzed 70–150 Hz HGA features derive from OpenNeuro ds006253; the archived source files and provenance are documented in the internal feature contribution. The exact dataset version recorded for this source is 1.0.3.