sciscape Publications
← All publications

Diagonal weight refitting showed no clear net call gain in eight SEEG patients

In 86 stimulation sites from eight patients, a rule that refits diagonal noise weights had a net call change of -1.30 percentage points against a rule that fits weights once. The paired patient bootstrap interval was -4.30 to 1.29 percentage points. Net calls equal after-pulse calls minus before-pulse calls. The test used five early calibration pulses and five later test pulses. The rank cutoff was 1/6. These reused clinical data do not establish a 5% false call rate or a neural response label.

SEEG · conformal ranking · neural response detection · noise weighting · brain interfaces

Admitted 2 citing publications

References

3
  1. usesA fixed spatial noise rule gave no clear 20 to 500 ms AUC gain after five early pulses in eight SEEG sessions sci:sha256:48f93098d9fe4ee439817f49e745f4c586103d8b79d4985cbb51b1bf7dc5d020

    Uses the selected SEEG cohort, exact compact source products, source metadata, and earlier source audits.

  2. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analysis uses the SEEG cohort and source products from OpenNeuro ds004696 version 1.0.1.

  3. usesdoi:10.1523/JNEUROSCI.2201-22.2023

    This is the source study associated with the OpenNeuro SEEG recordings analyzed here.

Cited by

2 publications

Public catalog entries on Sciscape.