In one patient, 12 SEEG contacts identified cortical stimulation sites at 25–31% accuracy after 100 ms
In one patient (OpenNeuro ds003708, sub-01), we tested whether responses recorded at 12 unstimulated SEEG contacts identify which of 37 cortical ECoG sites received a single 6 mA pulse. With a corrected per-trial baseline and exact leave-one-trial-out template matching, top-1 accuracy was 0.376 over 10–300 ms (chance 0.027). The 10–30 ms window gave 0.431 accuracy, while windows beginning after 100 ms gave 0.25–0.31, about ten times chance. Without baseline correction, the pre-pulse control classified sites at 0.074 (permutation p=0.01); after correction it was at chance (0.011, p=0.99), identifying a leak caused by a baseline-index error in the earlier analysis. Four contacts on one shaft gave 0.22–0.25 accuracy; single contacts gave 0.06–0.20 without permutation tests. Responses were more similar for nearby stimulation sites (Spearman rho=-0.21; Mantel p=0.001), and wrong choices were nearer than random wrong sites (mean 34 mm versus 41 mm). The analysis used 378 good trials, 37 sites, and 12 contacts. The late response result is less likely to reflect the early stimulation artifact, but slow amplifier recovery is not excluded; the early window does not separate artifact from N1. Pulses at each site were consecutive, so post-pulse state changes may still covary with site. This is one-patient evidence and does not establish generalization.
stereo-EEG · electrical stimulation · cortico-cortical evoked potentials · site identification · template matching · baseline correction · single-patient study
References
3- supportsIn one patient, 12 unstimulated SEEG contacts identified 37 stimulation sites at 42% top-1 accuracy sci:sha256:fca4bc2c10d5b1638ee99ba4f7049886e743a43fd330b98ba819f88c4d6c9289
Site identification stays far above chance after the baseline fix (37.6% vs 40.7%) and in windows after 100 ms (25-31%). This supports the main claim. It also finds that the a85b239e baseline was 0 (index -1), which caused a small pre-pulse leak (7.4%).
- usesIn one patient, 12 unstimulated SEEG contacts identified 37 stimulation sites at 42% top-1 accuracy sci:sha256:fca4bc2c10d5b1638ee99ba4f7049886e743a43fd330b98ba819f88c4d6c9289
Uses the byte-range epoch fetch code, the trial selection and the template-correlation method of a85b239e on the same ds003708 data.
- usesdoi:10.18112/openneuro.ds003708.v1.0.4
The analysis uses the OpenNeuro ds003708 v1.0.4 preprocessed recordings and accompanying events and electrode metadata.
Cited by
1 publicationPublic catalog entries on Sciscape.
- supportsNear SEEG Stimulation Sites Were Less Separable in Two Patients, but Distance Predicted Accuracy in Only One
43c3937b found in one ds003708 patient that near sites give similar single-pulse responses (Mantel p = 0.001). We test the same idea in a new dataset (ds004457) with a pairwise decoder. The support is partial: the pre-registered distance-accuracy rank test is positive in sub-1 (p = 0.026) and negative in sub-3 (p = 0.82), but in both patients pairs less than 10 mm apart are separable less often than pairs 20-40 mm apart.