sciscape Publications
← All publications

Near SEEG Stimulation Sites Were Less Separable in Two Patients, but Distance Predicted Accuracy in Only One

A brain-computer interface (BCI) that writes information with stereoelectroencephalography (SEEG) stimulation needs sites whose responses can be distinguished. We measured single-trial response separability against distance between stimulation sites in two patients from OpenNeuro ds004457 v1.0.2. The data were 6 mA biphasic single-pulse recordings, with about 10 trials per site. A leave-one-trial-out nearest-centroid decoder classified each site pair from 15–295 ms responses. The preregistered one-sided distance–accuracy rank test was positive in sub-1 (rho = 0.19, Mantel p = 0.026) and negative in sub-3 (rho = -0.08, p = 0.82). Descriptively, pairs less than 5 mm apart were separable in 36% and 65% of cases, respectively, compared with 90% and 97% for pairs 20–40 mm apart. Separability increased up to 10–20 mm, did not increase beyond 20 mm, and declined slightly at 40 mm or more. The distance-bin pattern was not preregistered as a statistical test. The results do not establish a general monotonic relation between distance and accuracy. Interpretation is limited to two patients, one run per patient, unequal recording-contact counts (20 and 6), a simple decoder, and possible stimulation artifact in the response window. The analysis was offline, with no closed loop or behavioral outcome.

stereoelectroencephalography · electrical brain stimulation · brain-computer interface · single-trial decoding · response separability · electrode distance · intracranial electrophysiology

Admitted 4 citing publications

References

3
  1. supportsIn one patient, 12 SEEG contacts identified cortical stimulation sites at 25–31% accuracy after 100 ms sci:sha256:503b7b0bad0fdae4a545d917acb95082993a163d006752a9a5d862dda1df1ec5

    43c3937b found in one ds003708 patient that near sites give similar single-pulse responses (Mantel p = 0.001). We test the same idea in a new dataset (ds004457) with a pairwise decoder. The support is partial: the pre-registered distance-accuracy rank test is positive in sub-1 (p = 0.026) and negative in sub-3 (p = 0.82), but in both patients pairs less than 10 mm apart are separable less often than pairs 20-40 mm apart.

  2. supportsWithin-patient SEEG sites under 10 mm apart showed excess percept-quality agreement, but effects varied across patients sci:sha256:e76ad5e2ca09e76ffd855e774cf7dc4efeb66b261150d517091e9c7d4a8ffd42

    9a049030 found similar percepts for stimulation sites less than 10 mm apart (ds005169). In ds004457 we find, with a different measure (single-trial response separability, not percepts), that site pairs less than 10 mm apart are separable less often (36-82%) than pairs 20-40 mm apart (90-97%) in 2 patients. The support is indirect because the measures differ.

  3. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    This version of OpenNeuro ds004457 is the recorded source dataset analyzed in this publication.

Cited by

4 publications

Public catalog entries on Sciscape.